IBM Support

PM55052: ABEND0C4 OCCURS WHEN LIU INTEGRITY CHECKER RUNS IN BATCH PROGRAMS IN IMS V9 OR V10 ENVIRONMENT 11/12/28 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After APAR PM52711 is applied, when running batch programs in
    IMS V9 or V10 environment with DBRC=Y and STEPLIB DD which
    concatenates library of LIU, LIU Integrity Checker causes
    ABENDS0C4.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 1 (FMID=H27P210) users     *
    *                 who use the Integrity Checker and the        *
    *                 Consistency Checker.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: After APAR PM52711 is applied,          *
    *                      Integrity Checker gets ABEND0C4 in the  *
    *                      FABLRTS0 module in Consistency Checker  *
    *                      or a batch program under IMS V9 or V10  *
    *                      environment.                            *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    After APAR PM52711 is applied, when running a batch program with
    Integrity Checker under IMS V9 or V10, Integrity Checker causes
    ABEND0C4 because IMS version check process does not work
    correctly in FABLRTS0 module.
    
    This problem occurs in following batch programs:
    
     - Consistency Checker with CHKRECON=YES in the SYSIN data set.
     - Batch program which uses DSPURX00 internally with STEPLIB DD
       which concatenates library of IMS Library Integrity
       Utilities and DBRC=Y specified.
    
    This error occurs under the following conditions:
    
     - Under IMS V9 or V10
     - APAR PM52711 is applied
    

Problem conclusion

  • The following module has been fixed to check IMS version
    correctly.
    
      FABLRTS0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM55052

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-12-27

  • Closed date

    2012-01-18

  • Last modified date

    2012-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK75537

Modules/Macros

  • FABLRTS0
    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R210 PSY UK75537

       UP12/01/21 P F201 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: