A fix is available
APAR status
Closed as program error.
Error description
Abend error recovery loop causing High CPU in KO2ACONB. Repeated abend0C6 and FRRs seen in IP SYSTRACE ALL: . 00-0144 00762C68 *PGM 006 070C4000 F011185F 00020006 00000000 00-0144 00762C68 *RCVY PROG 940C6000 00000006 00-0144 00762C68 SSRV 78 812D1602 4000EF50 00000998 00-0144 00762C68 *RCVY FRR 070C4000 C2F5E0CC 940C6000 00000006 00-0144 00762C68 *RCVY RTRY 070C4000 C2F5C27A 140C6000 00000006 Additional sysmptoms: ABEND 0C4 PIC10 IN KEY0 FOR KO2OCNTB+02095C ABENDS0C4-6 in KO2XTH2+17C at PM42983 level. The error recovery improvements will be included into the APAR.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON collector * * - The component that transfers DB2 * * monitoring data collected by the * * OMEGAMON collector to the TEMA * **************************************************************** * PROBLEM DESCRIPTION: Abend error recovery loop causes high * * CPU usage by OMPE. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: Abend error recovery loop causes high CPU in KO2ACONB. PROBLEM CONCLUSION: Code changed to improve error recovery.
Problem conclusion
Code changed to improve error recovery. KEYWORDS : HIGH CPU ABEND ERROR RECOVERY LOOP
Temporary fix
Comments
APAR Information
APAR number
PM53026
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-11-28
Closed date
2012-05-04
Last modified date
2012-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK78485
Modules/Macros
KO2APCAK KO2APCBA KO2APCBK KO2APCB2 KO2APCCA KO2APCCK KO2APCC2 KO2APCDA KO2APCDK KO2APCD2 KO2APCEA KO2APCEK KO2APCE2 KO2APCFA KO2APCFK KO2APCF2 KO2APCGA KO2APCGK KO2APCG2 KO2APCHA KO2APCHK KO2APCH2 KO2APCIA KO2APCIK KO2APCI2 KO2APCJA KO2APCJK KO2APCJ2 KO2APCKA KO2APCKK KO2APCK2 KO2APCLA KO2APCLK KO2APCL2 KO2APCMA KO2APCMK KO2APCM2 KO2APCNA KO2APCNK KO2APCN2 KO2APCOA KO2APCOK KO2APCO2 KO2APCPA KO2APCPK KO2APCP2 KO2APCQA KO2APCQK KO2APCQ2 KO2APC1A KO2APC1K KO2APC12 KO2APC2A KO2APC2K KO2APC22 KO2APC3A KO2APC3K KO2APC32 KO2APC4A KO2APC4K KO2APC42 KO2APC5K KO2APC6K KO2APC7K KO2APC8K KO2APC9A KO2APC9K KO2APC92 KO2APINK KO2ARSBA KO2ARSBK KO2ARSB2 KO2ARS0A KO2ARS0K KO2ARS02 KO2ARS1A KO2ARS1K KO2ARS12 KO2ARS2A KO2ARS2K KO2ARS22 KO2ARS3A KO2ARS3K KO2ARS32 KO2ARS4A KO2ARS4K KO2ARS42 KO2ARS5A KO2ARS5K KO2ARS52 KO2ARS6A KO2ARS6K KO2ARS62 KO2ARS7A KO2ARS7K KO2ARS72 KO2ARS8A KO2ARS8K KO2ARS82 KO2ASUAA KO2ASUAK KO2ASUA2 KO2ASUBA KO2ASUBK KO2ASUB2 KO2ASUDA KO2ASUDK KO2ASUD2 KO2ASU0A KO2ASU0K KO2ASU02 KO2ASU1A KO2ASU1K KO2ASU12 KO2ASU2A KO2ASU2K KO2ASU22 KO2ASU3A KO2ASU3K KO2ASU32 KO2ASU4A KO2ASU4K KO2ASU42 KO2ASU5A KO2ASU5K KO2ASU52 KO2ASU6A KO2ASU6K KO2ASU62 KO2ASU7A KO2ASU7K KO2ASU72 KO2ASU8A KO2ASU8K KO2ASU82 KO2ASU9A KO2ASU9K KO2ASU92 KO2ATD1B KO2ATD2B KO2ATD3B KO2ATRDB KO2ATSDB KO2ATSIB KO2ATSSB KO2ATSTB KO2ATVCB KO2ATVDB KO2ATVPB KO2ATVSB KO2ATVWB KO2CCINB KO2CCISA KO2CCISK KO2CCIS2 KO2CCNSA KO2CCNSK KO2CCNS2 KO2CDFCA KO2CDFCK KO2CDFC2 KO2CDFSA KO2CDFSK KO2CDFS2 KO2CDINA KO2CDINK KO2CDIN2 KO2CDSYA KO2CDSYK KO2CDSY2 KO2CIFIA KO2CIFIK KO2CIFI2 KO2CIF1A KO2CIF1K KO2CIF12 KO2CIF2K KO2CIF3A KO2CIF3K KO2CIF32 KO2CIF4A KO2CIF4K KO2CIF42 KO2CIF5A KO2CIF5K KO2CIF52 KO2CIF6A KO2CIF6K KO2CIF62 KO2CIF7A KO2CIF7K KO2CIF72 KO2CIF8A KO2CIF8K KO2CIF82 KO2CIMSB KO2CIMSC KO2CISBK KO2CLKDK KO2CMVSF KO2CNADB KO2CNTPK KO2CRLIE KO2CRLIF KO2CRLSE KO2CRLSF KO2CSTAB KO2CSTBB KO2CSTCB KO2CSTDB KO2CSTPK KO2CSTSB KO2CST1A KO2CST1K KO2CST12 KO2CST2A KO2CST2K KO2CST22 KO2CST3A KO2CST3K KO2CST32 KO2CST4A KO2CST4K KO2CST42 KO2CST5A KO2CST5K KO2CST52 KO2CST6A KO2CST6K KO2CST62 KO2CST7A KO2CST7K KO2CST72 KO2CSYSA KO2CSYSK KO2CSYS2 KO2CSY1K KO2CSY2A KO2CSY2K KO2CSY22 KO2CSY3A KO2CSY3K KO2CSY32 KO2CTHAK KO2CTHBA KO2CTHBK KO2CTHB2 KO2CTHCA KO2CTHCK KO2CTHC2 KO2CTHDK KO2CTHEK KO2CTHFK KO2CTHGA KO2CTHGK KO2CTHG2 KO2CTHHK KO2CTHIA KO2CTHIK KO2CTHI2 KO2CTHJA KO2CTHJK KO2CTHJ2 KO2CTHKK KO2CTHLA KO2CTHLK KO2CTHL2 KO2CTHMA KO2CTHMK KO2CTHM2 KO2CTHNA KO2CTHNK KO2CTHN2 KO2CTHOA KO2CTHOK KO2CTHO2 KO2CTHPK KO2CTHQA KO2CTHQK KO2CTHQ2 KO2CTHSA KO2CTHSK KO2CTHS2 KO2CTH1A KO2CTH1K KO2CTH12 KO2CTH2A KO2CTH2K KO2CTH22 KO2CTH5A KO2CTH5K KO2CTH52 KO2CTH6A KO2CTH6K KO2CTH62 KO2CTH9A KO2CTH9K KO2CTH92 KO2CTIMB KO2CT2SA KO2CT2SK KO2CT2S2 KO2CVTSC KO2CVTSF KO2CVTSG KO2DDSBA KO2DDSBK KO2DDSB2 KO2HSQPB KO2ICBCK KO2ICOLK KO2IINIK KO2IINTB KO2ITCAA KO2ITCAK KO2ITCA2 KO2LDSCB KO2NCSAB KO2NCSBB KO2NCS1B KO2NCS3B KO2NCS5B KO2NCS6B KO2NCS7B KO2NCS8B KO2NCS9B KO2NDRVB KO2OBUFB KO2OCINB KO2OCONB KO2ODBGB KO2ODINB KO2ODSTB KO2OEDAB KO2OEDBB KO2OEDCB KO2OEDSB KO2OED0B KO2OED1B KO2OED2B KO2OED3B KO2OED4B KO2OED5B KO2OED6B KO2OED7B KO2OED8B KO2OED9B KO2OINTB KO2OMSGB KO2ONAPB KO2ONASB KO2ONCYB KO2OQALA KO2OQALK KO2OQAL2 KO2ORCTB KO2ORLGB KO2OSBSB KO2OSTSB KO2OSYXB KO2OSY1B KO2OTCIA KO2OTCIK KO2OTCI2 KO2OTHAB KO2OTHBB KO2OTHDB KO2OTHEB KO2OTHGB KO2OTHHB KO2OTHJB KO2OTHKB KO2OTHLB KO2OTHMB KO2OTHNB KO2OTHOB KO2OTHPB KO2OTHQB KO2OTHSB KO2OTHTB KO2OTHUB KO2OTHVB KO2OTHWB KO2OTHXB KO2OTHYB KO2OTH3B KO2OTH4B KO2OTH5B KO2OTH6B KO2OTH7B KO2OTH8B KO2OTH9B KO2OXDVB KO2OXSYB KO2OXTHB KO2OXTRB KO2OXTSB KO2O225B KO2STOAB KO2STOBB KO2STORB KO2WTCAK KO2XBPSK KO2XCINB KO2XCISA KO2XCISK KO2XCIS2 KO2XDBSK KO2XDFSK KO2XDINK KO2XIMSB KO2XIMSC KO2XLKDK KO2XRCT3 KO2XRCT4 KO2XRCT5 KO2XRCT6 KO2XRCT7 KO2XRLIE KO2XRLIF KO2XRLSE KO2XRLSF KO2XSYSK KO2XSY1A KO2XSY1K KO2XSY12 KO2XSY2K KO2XSY3A KO2XSY3K KO2XSY32 KO2XSY4A KO2XSY4K KO2XSY42 KO2XSY5A KO2XSY5K KO2XSY52 KO2XSY6A KO2XSY6K KO2XSY62 KO2XTHSA KO2XTHSK KO2XTHS2 KO2XTH1A KO2XTH1K KO2XTH12 KO2XTH3A KO2XTH3K KO2XTH32 KO2ZSTO
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK78485
UP12/05/05 P F205