Fixes are available
Rational ClearQuest Fix Pack (8.0.0.1) for version 8.0
Rational ClearQuest Fix Pack (7.1.2.5) for version 7.1.2
Rational ClearQuest Fix Pack 14 (7.1.2.14) for 7.1.2
Rational ClearQuest Fix Pack 11 (8.0.0.11) for 8.0
Rational ClearQuest Fix Pack 12 (8.0.0.12) for 8.0
Rational ClearQuest Fix Pack 15 (7.1.2.15) for 7.1.2
Rational ClearQuest Fix Pack 13 (8.0.0.13) for 8.0
Rational ClearQuest Fix Pack 16 (7.1.2.16) for 7.1.2
Rational ClearQuest Fix Pack 17 (7.1.2.17) for 7.1.2
Rational ClearQuest Fix Pack 14 (8.0.0.14) for 8.0
Rational ClearQuest Fix Pack 18 (7.1.2.18) for 7.1.2
Rational ClearQuest Fix Pack 15 (8.0.0.15) for 8.0
Rational ClearQuest Fix Pack 19 (7.1.2.19) for 7.1.2
Rational ClearQuest Fix Pack 16 (8.0.0.16) for 8.0
Rational ClearQuest Fix Pack 17 (8.0.0.17) for 8.0
Rational ClearQuest Fix Pack 18 (8.0.0.18) for 8.0
Rational ClearQuest Fix Pack 19 (8.0.0.19) for 8.0
Rational ClearQuest Fix Pack 20 (8.0.0.20) for 8.0
Rational ClearQuest Fix Pack 21 (8.0.0.21) for 8.0
APAR status
Closed as program error.
Error description
In CQWeb 7.1.1.7 and 7.1.2.4 the following error message appears when trying to submit or modify a record after selecting a value for a field that has a value change hook.: Conflict error: Error from RPC server: PROPPATCH failed: The field 'XXX' cannot be modified because it is currently read-only.' The field XXX is actually a read-only field using a checkbox control in the form. Neither the fired value change hook nor the user is trying to set a value for it. This situation occurs only if the read-only checkbox field does not have a default value in its schema definition. Steps to reproduce: Using a sample database based on the DefectTracking schema: 1) Create a new SHORT_STRING field, myCheckbox, on the Defect record type 2) Set that field to READONLY in submitted state 3) Add a checkbox to the Defect_BASE_Submit form 4) Add a VALUE_CHANGED hook to the 'Project' field which sets the value of the Headline to some string 5) Check in the schema and upgrade the SAMPL database 6) Log in to CQWeb and submit a new Defect record on the SAMPLE database. 7) Before saving the record, select a value for the Project. The error message is thrown and the record cannot be saved. Workaround: Modify the schema to add a default value for the checkbox field.
Local fix
Problem summary
ClearQuest web client was displaying an error message appears when users try to submit or modify a record with a read-only checkbox control.
Problem conclusion
A fix is available in ClearQuest 7.1.1.8, 7.1.2.5, and 8.0.0.1
Temporary fix
Comments
APAR Information
APAR number
PM49180
Reported component name
CLEARQUEST WIN
Reported component ID
5724G3600
Reported release
711
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-10-03
Closed date
2012-05-30
Last modified date
2012-05-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLEARQUEST WIN
Fixed component ID
5724G3600
Applicable component levels
R712 PSN
UP
R800 PSN
UP
Document Information
Modified date: