A fix is available
APAR status
Closed as program error.
Error description
This is a code defect in the WL analytics code effecting the statistics displayed on the Worklight console which is misleading. The code defect has been identified for both the issues. For versioning a workaround is provided but the fix will address both the issues. WL analytics console is not displaying the new device count for each day when acccessed on different days which is caused by the raw data not bing properly sorted before compiled into the chart. WL Analytics is not supporting app version number that's not real number because the version numbers are currently stored as numbers rather than strings.
Local fix
Workaround for not supporting app version number that's not real number: Concerning the issue that analytics data for version 1.1.0 is not showing while that of version 2.0 is showing, this is indeed a defect of IWAP. The cause is that version numbers are treated as real numbers. Hence 1.1.0 would be considered an illegal expression and discarded and 2.0 is an acceptable number. Development team will work to fix this issue but for now could you ask the customer to use version numbers that are real numbers as a workaround.
Problem summary
**************************************************************** * USERS AFFECTED: * * All users who are using the Analytics Platform in the * * Worklight console to view data sent from devices. * **************************************************************** * PROBLEM DESCRIPTION: * * The data in the "New Devices" chart shown in the Worklight * * console for the Analytics platform is inconsistent. The * * information given for a particular day may be different when * * viewed at different times. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The code was changed so that data appears consistently. The fix for this APAR is currently targeted for fixpack 6.0.0.2.
Temporary fix
Comments
APAR Information
APAR number
PM99467
Reported component name
WORKLIGHT ENTER
Reported component ID
5725I4300
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-10-18
Closed date
2013-11-04
Last modified date
2013-11-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT ENTER
Fixed component ID
5725I4300
Applicable component levels
R600 PSY
UP