A fix is available
APAR status
Closed as program error.
Error description
When CTG_XA_MAX_TRAN specifies a small value, CICS TG fails to start and issues messages: CTG6686E Unable to initialize JNI library: [EXCI_NOT_AVAILABLE] CTG6513E CICS Transaction Gateway failed to initialize CTG0827W CTGBATCH Child completed with a non-zero return code 1 JNI trace shows: CTG9252T Exiting function 'xmt_addEntry' (return code '1006') CTG8642E Error storing XID (xmt_rc = 1006) There is not enough information to determine why the Gateway daemon fails to start. Additional search words: CTG6686 msgCTG6686E msgCTG6686 CTG6513 msgCTG6513E msgCTG6513 CTG0827 msgCTG0827W msgCTG0827 CTG8642 msgCTG8642E msgCTG8642
Local fix
Set CTG_XA_MAX_TRAN to 1000 or more.
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS Transaction Gateway. * **************************************************************** * PROBLEM DESCRIPTION: CICS TG does not provide enough * * information to determine the cause of * * errors occcuring because * * CTG_XA_MAX_TRAN specifies a small * * value. * **************************************************************** * RECOMMENDATION: * **************************************************************** When environment variable CTG_XA_MAX_TRAN was set lower than the number of heuristically-completed Units of Recovery (URs) retrieved from RRS during CICS TG start-up, CICS TG did not process all the returned URs and initialization failed. Additionally, for CICS TG V8.0 configured with CTG_EXCI_INIT=NO, if the number of heuristically-completed URs retrieved from RRS during CICS TG start-up exceeded the value set for CTG_XA_MAX_TRAN, then the Gateway daemon initialization complete successfully, but subsequent XA transactions failed with rc=-9 ECI_ERR_SYSTEM_ERROR. Non-XA transactions completed successfully. The documentation provided was not sufficient to determine the cause of the failures.
Problem conclusion
CICS TG has been changed. If CTG_XA_MAX_TRAN specifies a value lower than the number of incomplete URs retrieved from RRS during CICS TG start-up, the Gateway daemon fails to initialize. The description of environment variable CTG_XA_MAX_TRAN in CICS TG for z/OS Information Center has been updated: CTG_XA_MAX_TRAN Set this environment variable to limit the maximum number of concurrent XA transactions that can use the EXCI or IPIC protocol in a Gateway daemon. The range of values is 1 to 8192. The default value for a Gateway daemon is 1000. This variable requires a numeric entry. CICS Transaction Gateway allocates an amount of additional storage on startup approximately equivalent to 200 * the value of CTG_XA_MAX_TRAN bytes. For example, if the value of CTG_XA_MAX_TRAN is 1024, CICS Transaction Gateway allocates approximately 200 KB of additional storage on startup. This storage is also used during start up to process heuristically- completed units of recovery from the Gateway and any others in the same HA Group. For more information see "Highly available Gateway group" and "Cold Start". It is good practice to set the value of CTG_XA_MAX_TRAN to be 1000 or a value greater than the number of configured connection managers, which ever is the larger. The following messages have been updated: CTG6686E Unable to initialize JNI library: {error} Explanation: The ctgjni library could not be initialized. System Action: The CICS Transaction Gateway fails to start. User Action: The associated error gives more information about the cause. If the error indicates a problem locating the JNI library, ensure that it is available on the path shown by the error. If there was a security exception, ensure that the library has the correct access privileges. If the EXCI is unavailable, check the JNI log for further details. If the resource manager could not be started, check the JNI log for further details. After the error has been resolved start the CICS Transaction Gateway. CTG8642E Error storing XID (xmt_rc = {reason code}) Explanation: The CICS Transaction Gateway has received a request to start a transaction, but could not store temporary information needed to identify the transaction. System Action: The CICS Transaction Gateway cannot start the transaction. User Action: If the problem persists, increase the value of the 'CTG_XA_MAX_TRAN' environment variable for the Gateway. The default value is 1000. The following message has been introduced: CTG9250E Error storing information about {number of URs} heuristically-completed units of recovery (rc = {reason code}) Explanation: During the start of a Gateway with XA enabled, the initialization of the resource manager processes heuristically-completed transactions. These transactions may come from this Gateway or any Gateway in the same HA Group. For more information see the "Highly available Gateway group" and "Cold Start" sections of the CICS Transaction Gateway Information Center. The maximum number of units of recovery that can be processed is controlled by the environment variable 'CTG_XA_MAX_TRAN'. The default value is 1000. The first unit of recovery after this limit will cause initialization to stop. System Action: The CICS Transaction Gateway fails to start. User Action: As there are at least {number of URs} URs to process, the value needs to be increased. Use the RRS administrative panels in ISPF to find the number of URs in in-forget state for this Gateway and any others with the same APPLID qualifier.
Temporary fix
Comments
APAR Information
APAR number
PM93397
Reported component name
CTG V9 FOR Z/OS
Reported component ID
5655Y2000
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-07-19
Closed date
2013-07-22
Last modified date
2013-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK96061
Modules/Macros
CTG00201 CTG00204 CTG00470 CTG00471 CTG00524 CTG00555 CTG00565 CTG00567 CTG00568 CTG00591 CTG00592
SC34284300 |
Fix information
Fixed component name
CTG V9 FOR Z/OS
Fixed component ID
5655Y2000
Applicable component levels
R900 PSY UK96061
UP13/08/09 P F308
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: