Fixes are available
Rational Test Workbench 8.5.1
Rational Performance Test Server 8.5.1
Rational Test Virtualization Server 8.5.1
Rational Test Workbench Fix Pack 1 (8.5.1.1) for 8.5.1
Rational Test Virtualization Server Fix Pack 2 (8.5.1.2) for 8.5.1
Rational Performance Test Server Fix Pack 2 (8.5.1.2) for 8.5.1
Rational Integration Tester Fix Pack 2 (8.5.1.2) for 8.5.1
Rational Test Virtualization Server Fix Pack 3 (8.5.1.3) for 8.5.1
Rational Integration Tester Fix Pack 3 (8.5.1.3) for 8.5.1
Rational Integration Tester Fix Pack 4 (8.5.1.4) for 8.5.1
Rational Test Virtualization Server Fix Pack 4 (8.5.1.4) for 8.5.1
Rational Performance Test Server Fix Pack 5 (8.5.1.5) for 8.5.1
Rational Test Virtualization Server Fix Pack 5 (8.5.1.5) for 8.5.1
Rational Integration Tester Fix Pack 5 (8.5.1.5) for 8.5.1
Rational Performance Test Server Fix Pack 3 (8.5.1.3) for 8.5.1
Rational Performance Test Server Fix Pack 4 (8.5.1.4) for 8.5.1
APAR status
Closed as program error.
Error description
Iterate Test Data Action: Change number of iterations. Do not move focus out of text box. Save. Changed data not saved!
Local fix
Once a customer is aware they simply have to make a dummy change elsewhere on the form.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester * **************************************************************** * PROBLEM DESCRIPTION: * * If a user opens an existing Iterate Test Data action and * * only changes the number of iterations and and then saves the * * action without moving the focus from the text box the * * changes will not be saved. * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester 8.5.1 * ****************************************************************
Problem conclusion
This problem was resolved in Rational Integration Tester 8.5.1
Temporary fix
Comments
APAR Information
APAR number
PM92631
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-10
Closed date
2013-11-19
Last modified date
2013-11-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R850 PSN
UP
R851 PSY
UP
Document Information
Modified date:
02 November 2021