Error description
Rational Developer for System z - RDz - v8.5.1.1 Description : In the Remote System perspective, the 'properties-?mapping' value of a system library does not get saved between disconnect/ reconnect of the system. Customer has to enter the value every time he connects to the MainFrame. Steps to reproduce: A new workspace as well as the push-to-client feature and configuration files for resource mappings are needed. 1. create a new connection to a MVS which has configuration files for resource mappings, and connect to it 2. select 'MVS Files - Resource Mapping' check box in the opened 'Update Available' dialog 3. push the OK button 4. expand an RSE filter whose HLQ is not included in the downloaded configuration files in the RSE view 5. change a mapping property of a dataset in the expanded filter 6. disconnect and reconnect -? the changed mapping property is ignored Local fix : The extension can be hard-coded by using the File System Mapping.
Local fix
Problem summary
Local configuration files for the resource mapping were initialized on reconnecting when they were not included in downloaded configuration files.
Problem conclusion
The RDz client was fixed to save updated local configuration files even when they were not downloaded. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1.4 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM90368
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-06-04
Closed date
2013-10-16
Last modified date
2013-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 November 2021