Fixes are available
Rational Software Architect RealTime Edition 9.0
Rational Software Architect 9.0
Rational Software Architect for WebSphere Software 9.0
Rational Software Architect 8.5.5
Rational Software Architect for WebSphere Software 8.5.5
Rational Software Architect Fix Pack 1 (8.5.5.1) for 8.5.5
Rational Software Architect for WebSphere Software Fix Pack 1 (8.5.5.1) for 8.5.5
Rational Software Architect Fix Pack 2 (8.5.5.2) for 8.5.5
Rational Software Architect for WebSphere Software Fix Pack 2 (8.5.5.2) for 8.5.5
Rational Software Architect Fix Pack 3 (8.5.5.3) for 8.5.5
Rational Software Architect for WebSphere Software Fix Pack 3 (8.5.5.3) for 8.5.5
Rational Software Architect Fix Pack 4 (8.5.5.4) for 8.5.5
Rational Software Architect for WebSphere Software Fix Pack 4 (8.5.5.4) for 8.5.5
APAR status
Closed as program error.
Error description
After importing an IBM Rational Rose model containing a sequence diagram with two lifelines connected by a message, into IBM Rational Software Architect, the 'IRJA0131W Property 'operation' of '?Receive Operation Event?' ... 'warning message appears upon model validation. The following steps reproduce the error: 1. Open Rose 2. Add a sequence diagram to the Rose model 3. Add two classes to the Rose model, 'A' and 'B' 4. Add an operation 'foo' to class 'B' 5. Place the two classes onto the sequence diagram 6. Connect the lifelines with a message 7. Add the operation 'foo()' to the message 8. Save the changes and close Rose 9. Open RSA 10. Import the model into RSA 11. Validate the resultant model in RSA --?Result: The following warning message appears: 'IRJA0131W Property 'operation' of '?Receive Operation Event?' has 0 value(s); requires between 1 and 1'. There is a receive operation event without an operation, which the Rose Model Importer handles incorrectly. Workaround: Add the operation to the receive operation event.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** After Rose import, "IRJA0131W Property "operation" of "?Receive Operation Event?" ... warning appears and the receive operation event loses the operation.
Problem conclusion
The receive operation event was losing the operation during import. An operation is now set properly for the receive operation event during import.
Temporary fix
Comments
APAR Information
APAR number
PM87274
Reported component name
RATL SW ARCHITE
Reported component ID
5725A3000
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-18
Closed date
2013-06-14
Last modified date
2013-06-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL SW ARCHITE
Fixed component ID
5725A3000
Applicable component levels
R851 PSN
UP
Document Information
Modified date:
14 June 2013