A fix is available
APAR status
Closed as program error.
Error description
ABEND S0C4 occurs when running DRF with Integrity Checker using DBD generated by IMS V1.2.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 1 (FMID=H27P210) users who * * use the Integrity Checker utility and IMS * * Database Recovery Facility Version 3 * * Release 1 (FMID=H27L310) users or IMS * * Recovery Solution Pack Version 1 Release 1 * * (FMID=HAHM110) users who use the IMS * * Database Recovery Facility. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 occurs when running DRF with * * Integrity Checker using DBD generated * * by IMS V1.2. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** A DBD generated by IMS V1.3 or later has an internal table of DBD, DBDXTAB but a DBD generated by IMS V1.2 does not have the table. When running IMS Database Recovery Facility with Integrity Checker activated, Integrity Checker attempts to access the table when using a DBD even if the DBD is generated by IMS V1.2 and the table does not exist. In that case, the address of the table is not valid and accessing the address causes ABEND0C4.
Problem conclusion
The following modules and macros have been changed to fix the above problem: - FABLFBB0 - FABLFBB9 - FABLFBBA - FABLFBBB - FABLFBBC - FABLFBBD
Temporary fix
Comments
APAR Information
APAR number
PM83105
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-02-19
Closed date
2013-03-01
Last modified date
2013-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK92116
Modules/Macros
FABLFBBA FABLFBBB FABLFBBC FABLFBBD FABLFBB9
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R210 PSY UK92116
UP13/03/06 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 April 2013