A fix is available
APAR status
Closed as program error.
Error description
Message DSQ60246 FM error - retrieval of report record failed. Record not found is generated when specifying ACROSS usage on a Form.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V10 users. * **************************************************************** * PROBLEM DESCRIPTION: Error message DSQ60246 MSGDSQ60246 * * "FM error - retrieval of report record * * failed. Record not found." * * received when a form with usage code * * ACROSS is used on a SMALLINT column. * **************************************************************** * RECOMMENDATION: * **************************************************************** Code entered during the development of the QMF V10 release inadvertantly prevented the small integer data type from being properly processed when it was used in an ACROSS heading of a report.
Problem conclusion
Code allowing the SMALLINT data type to be processed has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PM81197
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-22
Closed date
2013-02-06
Last modified date
2013-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK91450
Modules/Macros
DSQFPACR
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
RA10 PSY UK91450
UP13/02/08 P F302
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: