PM79331: POSSIBLE CKZ27105E IN DB2ALTERBSDS SLB-START COMMAND WHEN CURRENT ACTIVE LOG HAS A START RBA OF ZERO

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Possible CKZ27105E in DB2ALTERBSDS SLB-START command when
    current active log has a start RBA of zero.
    
    CKZDYN01E Syntax error in value of DSName -1
    
    CKZ27105E ALLOCATION FAILED FOR DSN:
    
    Also corrected:
    
    Possible CKZ27110E in DB2ALTERBSDS SLB-START command when the
    high written RBA is less than the starting RBA of the current
    active log.
    
    CKZ27110E ERROR ACCESSING ACTIVE LOG; DDNAME: SYS00001 R15=0008
    ERROR=032 FUNCTION=POINT LOC=VLV11
    CKZ27110E RBA OF RECORD: FFFFFFFF_FFFFF000
    

Local fix

  • For CKZ27105E, do a -ARCHIVE LOG on the source DB2 systems so
    the current active log has a start RBA that is not zero. Then
    do a BACKUP SYSTEM and rerun the cloning.
    For CKZ27110E, stop and start the source DB2 systems so the
    high written RBA is in the current active log.Then do a BACKUP
    SYSTEM and rerun the cloning.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Possible CKZ27105E in DB2ALTERBSDS      *
    *                      SLB-START command when current active   *
    *                      log has a start RBA of zero.            *
    *                      CKZDYN01E Syntax error in value of      *
    *                       DSName -1                              *
    *                      CKZ27105E ALLOCATION FAILED FOR DSN:    *
    *                      Also corrected:                         *
    *                      Possible CKZ27110E in DB2ALTERBSDS      *
    *                       SLB-START command when the high        *
    *                      written RBA is less than the starting   *
    *                      RBA of the current active log.          *
    *                      CKZ27110E ERROR ACCESSING ACTIVE LOG;   *
    *                       DDNAME: SYS00001 R15=0008              *
    *                       ERROR=032 FUNCTION=POINT LOC=VLV11     *
    *                      CKZ27110E RBA OF RECORD:                *
    *                       FFFFFFFF_FFFFF000                      *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM79331

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-17

  • Closed date

    2012-12-21

  • Last modified date

    2013-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CKZ00246
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R220 PSY UK90597

       UP13/01/09 P F301

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021