A fix is available
APAR status
Closed as program error.
Error description
Headline/Abstract: *************************************************************** Rational Developer for System z (RDz): Outline view shows wrong level for PL/I procedures defined without END label. APAR Error Description: *************************************************************** Rational Developer for System z - RDz - V8.5.0.1 In a PL/I program, when defining procedures without 'END' labels, the Outline view shows the procedure at a wrong level. Re-creation steps: For instance, use the following code: testcas11: proc(pzparam) options(fetchable); dcl pzparam ptr; dcl pcmethode char(80); /* correct */ call correct1(); call correct2(); /* wrong */ call wrong1(); call wrong2(); call wrong3(); correct1: procedure; /* blaa */ end correct1; correct2: procedure; /* blaa */ end correct2; wrong1: procedure; /* blaa */ end; /* ?== No procedure name */ wrong2: procedure; /* blaa */ end; /* ?== No procedure name */ wrong3: procedure; /* blaa */ end; /* ?== No procedure name */ end testcas11; All procedures are defined on the same level (level 1), but the Outline View shows the following hierarchy: testcas11 +-correct1 -? level 1 +-correct2 -? level 1 +-wrong1 -? level 1 +-wrong2 -? level 2 ?== wrong +-wrong3 -? level 3 ?== wrong *************************************************************** Local fix: None
Local fix
Problem summary
In a PL/I program, when defining procedures without the procedure name on the end statement, the Outline view shows the subsequent procedures at a wrong level.
Problem conclusion
The PL/I Outline View has been fixed to handle procedures without the procedure name on the end statement. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1.1 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM78177
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-30
Closed date
2013-03-21
Last modified date
2013-03-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
29 October 2021