There is an error in the info center documentation http://pic.dhe.ibm.com/infocenter/tivihelp/v48r1/topic/com.ibm.s co.doc_2.3/enablement/implementationservices.html The doc does not have the correct information for the Windows_UploadFile in Table 6, it has the information for Windows_ExecuteCommand and Windows_UploadFileAndExecuteCommand The Windows_ExecuteCommand is incorrectly presented under the Windows_UploadFile in Table 6, in other words the information in the doc for the Windows_UploadFile is really the information for the Windows_ExecuteCommand. Also if we are providing an example, please provide Windows like paths and names, so instead of "HelloWorld.sh" use "HelloWorld.bat", or "/tmp" use "C:\temp". This is what I was expecting to see for the Windows interfaces Windows_UploadFile remoteMachine String Remote machine IP address or host name "10.10.1.9" userName String Login user name for the above protocol "Administrator" password String Unencrypted Login password "SomePassword" fileName String Name of the file to be uploaded from the local file repository "HelloWorld.bat" destinationPath String Full destination path in the format of the remote machine "C:\target\dir" localRepositorySubDir String Subdirectory or NULL/Empty string "SubFolder" Windows_ExecuteCommand remoteMachine String Remote machine IP address or host name "10.10.1.9" userName String Login user name for the above protocol "root" password String Unencrypted Login password "SomePassword" commandLine String Command line or script file "Dir" cmdLineWorkingDirectory String Full path "C:\target\dir" Windows_UploadFileAndExecuteCommand remoteMachine String Remote machine IP address or host name "10.10.1.9" userName String Login user name for the above protocol "Administrator" password String Unencrypted Login password "SomePassword" fileName String Name of the file to be uploaded from the local file repository "HelloWorld.bat" destinationPath String Full destination path in the format of the remote machine "C:\target\dir" localRepositorySubDir String Subdirectory or NULL/Empty string "SubFolder" makeFileExecutable Boolean Ignored on Windows operating systems null commandLine String Command line or script file "Dir" cmdLineWorkingDirectory String Full path "C:\target\dir" Also, please correct the way the informaiton is presented for the ExtractOutputMap and GetRemoteMachineDataFromVirtualMachineKey The Table 8 for ExtractOutputMap has the following: retValues |OutputMapValues |ErrCode + errMsg + retCode + stdOut | |+ stdErr In the BPD scripts the plus sign means concatenation. It would be better and more clear to indicate that they are part of a Complex Structure Type name OutputMapValues and list each entry in a separate line as follows retValues |OutputMapValues |ErrCode | |errMsg | |retCode | |stdOut | |stdErr The same for Table 9 Instead of virtualServerKey |VirtualServerKey |virtualSystemID + virtualServerID Present the entry of the table as virtualServerKey |VirtualServerKey |virtualSystemID | |virtualServerID and for Table 10, instead of RemoteMachineData |RemoteMachineCredentials |remoteMachine + remoteUser + remotePassword + privateKey + publicKey please use RemoteMachineData |RemoteMachineCredentials |remoteMachine | |remoteUser | |remotePassword | |privateKey | |publicKey Furthermore in this doc, the "Windows Excute Command" is also missing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of SmartCloud Orchestrator 2.3 which are using Scripting Utilities Toolkit. **************************************************************** * PROBLEM DESCRIPTION: Scripting Utilities Toolkit documentation. Function description Windows_UploadFile and Windows_ExecuteCommand are in parts missing and wrong. ****************************************************************
Problem conclusion
Here below you can see the documentation text that is going to be added to the infocenter: Windows_UploadFile This integration or implementation service uploads a file to a remote machine via RXA toolkit/protocol Input parameters Data type Expected value Sample data - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - remoteMachine String Remote machine IP address or host name "9.120.xxx.xxx✠userName String Login user name for the above protocol "Administrator✠password String Login password "**********✠fileName String Name of the file to be uploaded from the local repository. "HelloWorld.bat" destinationPath String Full destination path in the format of the remote machine "c:\tmp\destination\" localRepositorySubDir String Subdirectory or null/empty string. See File upload restrictions. "\SubFolder\" Windows_ExecuteCommand This integration or implementation service executes a command line on a remote machine via RXA toolkit/protocol. Input parameters Data type Expected value Sample data - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - remoteMachine String Remote machine IP address or host name "9.120.xxx.xxx✠userName String Login user name for the above protocol "Administrator✠password String Login password "**********✠commandLine String Command line or script file that must be executed on the remote machine. "dir✠cmdLineWorkingDirectory String Full path in the format of the remote machine "c:\tmp\destination\âœ
Temporary fix
Comments
APAR Information
APAR number
ZZ00207
Reported component name
SMRTCLOUD ORCHS
Reported component ID
5725H2800
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-01-28
Closed date
2014-02-10
Last modified date
2014-02-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMRTCLOUD ORCHS
Fixed component ID
5725H2800
Applicable component levels
R230 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4KMC","label":"IBM Cloud Orchestrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
03 November 2021