SE29685: WDSC-RSE-DSU-CHARACTERS ENTERED IN LOWER CASE IN PF FORMMAT AS "FRED" THE SYNTAX CHECKER ACCEPTS BUT FAILS AT COMPILATION TIME.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • If customer enters in lower case in PF formmat as "fred", syntax
    checker
    accepts it but fails when compiled.
    Keying in upper case the same "FRED", it's accepted by the
    syntax
    checker and compiles with success.
    

Local fix

  • Go into
    "Windows-->preference-->Remote Systems-->Remote Systems LPEX
    Editor-->iSeries Parsers--> DDS" and check "Automatic
    uppercasing"
    
    Then the lower case will be changed to upper case automatically.
    
    The syntax checker will be fixed.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users who edit DDS file in PF format using   *
    *                 RSE.                                         *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The DDS syntax checker does not         *
    *                      complain when record and field names    *
    *                      are entered in lowercase even though    *
    *                      that will cause a compile error.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    *                                                              *
    ****************************************************************
    The problem will be fixed in a WDSC v7.0.0.6 and RDi v7.1 .
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    SE29685

  • Reported component name

    WDSC6 RS EXPLOR

  • Reported component ID

    5722WDS03

  • Reported release

    600

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-10-04

  • Closed date

    2007-10-12

  • Last modified date

    2008-09-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WDSC6 RS EXPLOR

  • Fixed component ID

    5722WDS03

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCPQE5","label":"Remote System Explorer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
19 September 2008