Fixes are available
APAR status
Closed as program error.
Error description
When many rules are added, then deleted and added again, over several such cycles the ruleset generation may start taking a long time and possibly result in timeout/rollback exception. The step that seems to be taking most of the time in ruleset generation correspond to the typical stack trace excerpt : ... at ilog/rules/teamserver/model/impl/IlrAbstractCachingSession.findE lements(IlrAbstractCachingSession.java:254(Compiled Code)) at ilog/rules/teamserver/ejb/ruleset/IlrRulesetArchiveGenerator.fin dElementsAndRemoveDuplicates(IlrRulesetArchiveGenerator.java:754 ) at ilog/rules/teamserver/ejb/ruleset/IlrRulesetArchiveGenerator.add RuleArtifactsToArchiveBuilder(IlrRulesetArchiveGenerator.java:67 5) at ilog/rules/teamserver/ejb/ruleset/IlrRulesetArchiveGenerator.gen erateRulesetArchive(IlrRulesetArchiveGenerator.java:246) at ilog/rules/teamserver/ejb/service/IlrSessionFacadeImpl.generateR CEArchive(IlrSessionFacadeImpl.java:4025) at ilog/rules/teamserver/ejb/service/IlrSessionFacadeImpl.generateR ulesetArchive(IlrSessionFacadeImpl.java:3979) This also affects the time taken to display a large number of artifacts in a Smart View.
Local fix
Configure projects to be "Build automatically" or through the Settings wizard set the configuration parameter "teamserver.build.elementOnCommit" to true
Problem summary
The queries used to select the rules use outer join and views with Derby that are too slow for this process
Problem conclusion
The code is fixed
Temporary fix
Comments
APAR Information
APAR number
RS01700
Reported component name
WS DECISION CTR
Reported component ID
5725B6900
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-08-01
Closed date
2014-08-05
Last modified date
2014-08-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
None 999
Fix information
Fixed component name
WS DECISION CTR
Fixed component ID
5725B6900
Applicable component levels
R851 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSQP76","label":"IBM Operational Decision Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 January 2022