Error description
When Physical Volumes are specified for new copies of Logical Volume in the mirrorvg command, allocation of Physical Partitions on Physical Volumes is not in the order of Physical Volumes specified in the command line. A snippet to explain the above: mkvg -y wu32748vg -f hdisk1 hdisk2 hdisk3 hdisk4 hdisk5 hdisk6 mklv -y wu32748lv -e x -s s wu32748vg 3 hdisk1 hdisk2 hdisk3 mirrorvg -s -m -c 2 wu32748vg hdisk4 hdisk5 hdisk6 lslv -m wu32748lv $ lslv -m wu32748lv wu32748lv:N/A LP PP1 PV1 PP2 PV2 PP3 PV3 0001 0161 hdisk1 0161 hdisk5 0002 0161 hdisk2 0161 hdisk6 0003 0161 hdisk3 0161 hdisk4
Local fix
Run mirrorvg without -m. mkvg -y wu32748vg -f hdisk1 hdisk2 hdisk3 hdisk4 hdisk5 hdisk6 mklv -y wu32748lv -e x -s s wu32748vg 3 hdisk1 hdisk2 hdisk3 mirrorvg -s -c 2 wu32748vg hdisk4 hdisk5 hdisk6 lslv -m wu32748lv $ lslv -m wu32748lv wu32748lv:N/A LP PP1 PV1 PP2 PV2 PP3 PV3 0001 0161 hdisk1 0161 hdisk4 0002 0161 hdisk2 0161 hdisk5 0003 0161 hdisk3 0161 hdisk6
Problem summary
mirrorvg -m has some logic that can mix up the order of the disks that an LV is currently allocated on. When this happens, the newly allocated copies of the LV will not use the PVs in the order they were listed on the command line. This happens when the LV is allocated on PVs in an order that is not the same as if those PVs are sorted by pvid. Note that there are sometimes when mirrorvg -m must rearrange disks when allocating new copies so that those new copies can be an exact map of the existing copies. But in some cases, when all disks are the same size, mirrorvg is re-ordering disks when it doesn't need to.
Problem conclusion
Change mirrorvg -m logic to not re-order PVs in this case when it is not necessary, but just being done as an easy way to get unique pvids the LV is allocated on.
Temporary fix
Comments
6100-07 - use AIX APAR IV58727 6100-08 - use AIX APAR IV58655 6100-09 - use AIX APAR IV58084 6100-09 - use AIX APAR IV58084 6100-09 - use AIX APAR IV58084 7100-01 - use AIX APAR IV58239 7100-02 - use AIX APAR IV58175 7100-03 - use AIX APAR IV56029 7100-04 - use AIX APAR IV58091
APAR Information
APAR number
IV56029
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2014-02-27
Closed date
2014-03-25
Last modified date
2016-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U859005
UP14/05/22 I 1000
PTF to Fileset Mapping
U859005 bos.rte.lvm 7.1.3.15
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]