Error description
AIX command chuser fails to update boolean attributes for ldap users if the server is windows AD.
Local fix
Problem summary
chuser command fails to changes boolean attribute values when AIX is configured as LDAP client to Windows AD server for LDAP users.
Problem conclusion
Checking peroper LDAP server schema, based on that the LDAP user's request will be handled by the LDAP client.
Temporary fix
Comments
6100-07 - use AIX APAR IV53700 6100-08 - use AIX APAR IV58040 6100-09 - use AIX APAR IV53694 6100-09 - use AIX APAR IV53694 6100-09 - use AIX APAR IV53694 7100-01 - use AIX APAR IV57685 7100-02 - use AIX APAR IV53445 7100-03 - use AIX APAR IV53696
APAR Information
APAR number
IV53694
Reported component name
AIX 610 STD EDI
Reported component ID
5765G6200
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2014-01-04
Closed date
2014-01-04
Last modified date
2014-08-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 610 STD EDI
Fixed component ID
5765G6200
Applicable component levels
R610 PSY U859288
UP14/05/21 I 1000
PTF to Fileset Mapping
U859288 bos.rte.security 6.1.9.15