A fix is available
APAR status
Closed as program error.
Error description
************************************************************** * USERS AFFECTED: * Systems running the AIX 7200-01 Technology Level * with bos.cluster.rte at or below the 7.2.1.3 level. ************************************************************** * ERROR DESCRIPTION: * PowerHA Verify & Sync, clcmd, or other processes that * utilize clcomd may hang. * Large numbers of zombie processes for clcmd, clmgr, or * similar commands may be seen if this is occurring. * * Restarting clcomd with stopsrc/startsrc will clean up zombie * processes and allow clcomd to process new events again; * however the issue could re-occur again later, until the fix * is applied. ************************************************************** * RECOMMENDATION: * Install APAR IJ04267. * Prior to fix availability, an interim fix is available from * either * ftp://aix.software.ibm.com/aix/ifixes/ij04267/ * https://aix.software.ibm.com/aix/ifixes/ij04267/ * The ifix can be installed using Live Update (LU). * If LU is not used, installation of the ifix requires a * reboot. **************************************************************
Local fix
Stopping and restarting clcomd (stopsrc -s clcomd; startsrc -s clcomd) will allow clcomd to process new events, and clean up existing zombie processes. However, it will not prevent further hangs.
Problem summary
Operations involving clcomd, such as PowerHA Verify & Sync and clcmd commands may hang.
Problem conclusion
Remove unnecessary connection conflict logic that led to an infinite loop of clcomd refreshes.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
IJ04267
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Submitted date
2018-02-19
Closed date
2018-03-05
Last modified date
2019-01-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
R720 PSY U878987
UP19/01/23 I 1000
PTF to Fileset Mapping
U878987 bos.cluster.rte 7.2.1.4
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVEF8","label":"AIX 7.2 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"","label":""}}]