APAR status
Closed as fixed if next.
Error description
The ld command would display the undefined symbol error for a symbol being defined in an object file specified with the ld -o option. ld: 0711-317 ERROR: Undefined symbol: <symbol>
Local fix
The customer may specify the ld -bkeepfile option for the 64 bit inode object file to avoid the error.
Problem summary
ld command fails when input files are in a file system using 64-bit inode numbers.
Problem conclusion
Temporary fix
Comments
This APAR is being closed FIN. This means that a solution to this APAR is expected to be delivered from IBM in a release (if any) to be available within the next 24 months.
APAR Information
APAR number
IV41302
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Submitted date
2013-05-02
Closed date
2014-03-26
Last modified date
2014-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R710 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: