A fix is available
APAR status
Closed as program error.
Error description
Interface using HEA adapter will stop receiving data on P7 machines. This issue will not be seen on P6 machines. Component traces will have Rrh3 trace.
Local fix
Problem summary
Interface using HEA adapter will stop receiving data on P7 machines. This issue will not be seen on P6 machines. Component traces will have Rrh3 and may be Rrh2 trace.
Problem conclusion
Forced P7 processor to execute in order at this point.
Temporary fix
Comments
5300-08 - use AIX APAR IZ64165 5300-09 - use AIX APAR IZ64166 5300-10 - use AIX APAR IZ64167 5300-11 - use AIX APAR IZ64168 5300-12 - use AIX APAR IZ64823 6100-01 - use AIX APAR IZ64169 6100-02 - use AIX APAR IZ64170 6100-03 - use AIX APAR IZ64171 6100-05 - use AIX APAR IZ62833 6100-04 - use AIX APAR IZ64053 6100-05 - use AIX APAR IZ62833 6100-06 - use AIX APAR IZ64457 7100-00 - use AIX APAR IZ86386
APAR Information
APAR number
IZ64168
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2009-11-02
Closed date
2009-11-04
Last modified date
2013-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U829870
UP10/02/08 I 1000
PTF to Fileset Mapping
U829870 devices.chrp.IBM.lhea.rte 5.3.11.1