APAR status
Closed as program error.
Error description
When musentdd driver receives non vlan tag packet of size 1515, 1516, 1517 or 1518 bytes, it stops receiving packets while transmit still works.
Local fix
Problem summary
When FC5899 adapter receives non vlan tag packet of size 1515, 1516, 1517 or 1518 bytes, it stops receiving packets while transmit still works.
Problem conclusion
Code modified to set the maximum Rx frame size in a Receive Producer Buffer Descriptor register to 1536.
Temporary fix
Comments
APAR Information
APAR number
IV82421
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-08
Closed date
2016-03-08
Last modified date
2016-11-09
APAR is sysrouted FROM one or more of the following:
IV80569
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U869372
UP16/06/21 I 1000
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
19 April 2022