A fix is available
APAR status
Closed as program error.
Error description
Cron job scheduled at 3:00 am after DST changes will not run.
Local fix
Problem summary
Cron job scheduled at 3:00 am after DST changes will not run.
Problem conclusion
Cron code is modified to check for job scheduled just after DST occurs and handle those jobs accordingly.
Temporary fix
Comments
5300-10 - use AIX APAR IZ82703 5300-11 - use AIX APAR IZ82201 5300-12 - use AIX APAR IZ81589 6100-03 - use AIX APAR IZ79386 6100-04 - use AIX APAR IZ78949 6100-05 - use AIX APAR IZ78896 6100-06 - use AIX APAR IZ74244 7100-00 - use AIX APAR IZ88984
APAR Information
APAR number
IZ82703
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2010-08-11
Closed date
2010-08-11
Last modified date
2013-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U837893
UP10/09/20 I 1000
PTF to Fileset Mapping
U837893 bos.rte.cron 5.3.10.3