A fix is available
APAR status
Closed as program error.
Error description
A timing hole exists in the pty code. If the pty is told to flow control off and then the socket disconnects, the close will loop forever.
Local fix
Problem summary
system hung with pty_close routine.
Problem conclusion
Availability of message is checked and the message queue is enabled.
Temporary fix
Comments
5300-09 - use AIX APAR IZ82436 5300-10 - use AIX APAR IZ82704 5300-11 - use AIX APAR IZ82202 5300-12 - use AIX APAR IZ81590 6100-02 - use AIX APAR IZ79533 6100-03 - use AIX APAR IZ79389 6100-04 - use AIX APAR IZ78950 6100-05 - use AIX APAR IZ78898 6100-06 - use AIX APAR IZ73901 7100-00 - use AIX APAR IZ88989
APAR Information
APAR number
IZ82202
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2010-08-09
Closed date
2010-08-09
Last modified date
2013-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U837659
UP10/09/20 I 1000
PTF to Fileset Mapping
U837659 bos.rte.tty 5.3.11.2
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]