IBM Support

VM66185: INSTUPGR STAGE2 (PRIME COMMAND PRODUCES FPLRVR238E

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The command "INSTUPGR STAGE2 (PRIME" can complete successfully
    but can produce Pipelines error message FPLRVR238E.
    The INSTS2FC EXEC, which is run during INSTUPGR STAGE2
    processing, can produce the following messages:
                                                                   .
    FPLRVR238E Record count "" not zero or positive
    FPLMSG003I ... Issued from stage 1 of pipeline 1
    FPLMSG001I ... Running "STEM WNG CMNT."
    FPLRVR238E Record count "" not zero or positive
    FPLMSG003I ... Issued from stage 1 of pipeline 1
    FPLMSG001I ... Running "STEM WNG CMNT."
    FPLRVR238E Record count "" not zero or positive
    FPLMSG003I ... Issued from stage 1 of pipeline 1
    FPLMSG001I ... Running "STEM WNG CMNT."
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/VM                            *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
         While performing Upgrade In Place (UIP) installation to
    upgrade from z/VM 6.4.0 to z/VM 7.1.0, the command
    INSTUPGR STAGE2 (PRIME)
    completes successfully but produces Pipeline messages:
                                                                   .
    FPLRVR238E Record count "" not zero or positive
    FPLMSG003I ... Issued from stage 1 of pipeline 1
    FPLMSG001I ... Running "STEM WNG CMNT."
    FPLRVR238E Record count "" not zero or positive
    FPLMSG003I ... Issued from stage 1 of pipeline 1
    FPLMSG001I ... Running "STEM WNG CMNT."
    FPLRVR238E Record count "" not zero or positive
    FPLMSG003I ... Issued from stage 1 of pipeline 1
    FPLMSG001I ... Running "STEM WNG CMNT."
                                                                   .
         The problem is in INSTS2FC EXEC.  In the Write_Warning
    routine after the data in the wng_cmnt. stem is written to the
    log files, the stem is re-initialized incorrectly.
    

Problem conclusion

  • INSTS2FC $EXEC has been updated.  In the Write_Warning
    routine, the initialization of the wng_cmnt. stem has been
    corrected.
    

Temporary fix

  • FOR RELEASE VM/ESACP/ESAR710 :
    PREREQ: NONE
    CO-REQ: NONE
    IF-REQ: NONE
    

Comments

APAR Information

  • APAR number

    VM66185

  • Reported component name

    VM CP

  • Reported component ID

    568411202

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-07-11

  • Closed date

    2018-07-17

  • Last modified date

    2018-09-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UM35339

Modules/Macros

  • INSTS2FC
    

Fix information

  • Fixed component name

    VM CP

  • Fixed component ID

    568411202

Applicable component levels

  • R710 PSY UM35339

       UP18/07/19 P 1801

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]

Document Information

Modified date: