IBM Support

PM92703: RECOVERY JOB TRIES TO START THE DATABASE BEFORE THE DBR HAS COMPLETED ON OTHER IMS SYSTEMS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Recovery job tries to start the database before the DBR has
    completed on other IMS systems.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IRP V1R1 with INDEX might be        *
    *                 affacted.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: SWI OLDS was performed two times if we  *
    *                      have INDEXes to DBR.                    *
    *                      ALso some INDEXes are DBRed two times   *
    *                      if they are on the Recovery List        *
    *                      already.                                *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    We should do SWI OLDS only once during a recovery process,
    also if an INDEX is already in the recovery list, we should
    not add it to the index list for DBR/STA.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PM92703

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-10

  • Closed date

    2013-08-02

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK96408

Modules/Macros

  • FRXSDR00 FRXVRCV0 FRXVSTA0 FRXVSTA2
    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R110 PSY UK96408

       UP13/08/07 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 September 2013