A fix is available
APAR status
Closed as program error.
Error description
Change ANALYZEPART report to display 100 byte, or more, key lengths
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All clients of IMS HALDB Toolkit V3R2 * **************************************************************** * PROBLEM DESCRIPTION: Previously, HALDB Toolkit printed up to * * 64 bytes of the Root High Key in the * * Key: Field of the Partitioning Report * * for the MAINTAIN and ANALYZEPART * * functions. * **************************************************************** * RECOMMENDATION: * **************************************************************** The Key: field now allows for up to 112 bytes for the Root High Key on the Partitioning report for the MAINTAIN and ANALYZEPART functions.
Problem conclusion
Module IHCWWANA was changed to allow for up to 112 bytes.
Temporary fix
Comments
APAR Information
APAR number
PM85235
Reported component name
IMS HALDB C&M A
Reported component ID
5655I0100
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-03-20
Closed date
2013-03-26
Last modified date
2014-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK92881
Modules/Macros
IHCULEV0 IHCWWANA
Fix information
Fixed component name
IMS HALDB C&M A
Fixed component ID
5655I0100
Applicable component levels
R320 PSY UK92881
UP13/03/27 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: