Error description
When data is found for the objects being tracked in over 1,000 archive logs a S0C4 abend can occur in module ALAGEN1 due to an internal table overflow.
Local fix
Reduce the number of logs that are being processed by reducing the reporting time frame and/or the objects being reported.
Problem summary
**************************************************************** * USERS AFFECTED: Uaser of ALA350 * **************************************************************** * PROBLEM DESCRIPTION: When data is found for the objects * * being tracked in over 1,000 * * archive logs a S0C4 abend can occur in * * module ALAGEN1 due to * * an internal table overflow. * * * * * * * * * * * **************************************************************** * RECOMMENDATION: Apply the PTF * ****************************************************************
Problem conclusion
Apply the PTF
Temporary fix
Comments
APAR Information
APAR number
PI90257
Reported component name
DB2 LOG ANALYSI
Reported component ID
5655E6601
Reported release
350
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-14
Closed date
2017-12-05
Last modified date
2018-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ALABSDM
Fix information
Fixed component name
DB2 LOG ANALYSI
Fixed component ID
5655E6601
Applicable component levels
R350 PSY UI52404
UP17/12/13 P F712
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.5.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 January 2018