A fix is available
APAR status
Closed as program error.
Error description
Abend 5C6-00940024 dump was issued by WebSphere Application Server Control Region (CR) region when the stop command was issued for the WebSphere Application Server. The WebSphere server did not stop. . Queue Sharing Group QSG
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: Abend 5C6-00940024 may occur when a * * WebSphere Application Server has a * * bindings mode connection to both a * * Queue Manager name and a Queue Sharing * * Group name. * **************************************************************** * RECOMMENDATION: * **************************************************************** WSAS with bindings mode connections. A first connection is made with a QMGR name, the connection will succeed and complete normally. If subsequent connections are made using a QSG name, the connection to the QMGR will complete successfully. However when the address space attempts to disconnect from MQ, abend 5C6-00940025 may occur due to the control blocks for the connection's RRS context not being owned by the QMGR the application connected to when the QSG name was specified.
Problem conclusion
Processing for connections to a QSG has been updated for this scenario, to correctly set the preferred QMGR token during the first connect to the QSG, when a previous QMGR connection has already occurred. 100Y CSQBCON CSQ3ID00
Temporary fix
Comments
APAR Information
APAR number
PI65237
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-01
Closed date
2016-09-09
Last modified date
2016-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CSQBCON CSQ3ID00
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R100 PSY UI40734
UP16/10/06 P F610