IBM Support

PI50878: ENABLE MAXLOGS RC PARAMETER FOR 2-STEP BATCH AND ISPF MODES FOR HPCA

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Enable MAXLOGS RC parameter for 2-step batch and ISPF modes for
    HPCA.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM IMS High Performance Change          *
    *                 Accumulation Utility users of the            *
    *                 Maximum Log related parameters.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: No default MAXLOGS RC/MAXLGRC is set    *
    *                      if the MAXIMUM LOGS=/MAXLOGS=           *
    *                      parameters are used but                 *
    *                      MAXLOGS RC/MAXLGRC are omitted.         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF for APAR PI50878.                  *
    ****************************************************************
    HPCABAT0 does not ensure a MAXLOG RC value.  This leads to the
    job finishing with RC=0 and no HPC1310I message is issued even
    though the MAXIMUM LOGS threshold is met.
    HPCSBAT0 omits the syntax and use/meaning of MAXLGRC and this
    is not intuitive.
    

Problem conclusion

Temporary fix

Comments

  • HPCABAT0 is changed to check for parameter MAXLOG
    RC=nn/MAXLGRC=nn if parameter MAXIMUM LOGS=nnn/MAXLOGS=nnn is
    specified.  If MAXIMUM LOGS=nnn/MAXLOGS=nnn is specified but
    MAXLOG RC=nn/MAXLGRC=nn is omitted, then default return code
    value 1 is set for MAXLOG RC=nn/MAXLGRC=nn.
    
    HPCSBAT0 in SHPCSAMP is updated to show the syntax and meaning
    of the MAXLGRC parameter.
    

APAR Information

  • APAR number

    PI50878

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    110

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-20

  • Closed date

    2018-01-16

  • Last modified date

    2018-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI53222

Modules/Macros

  • HPCABAT0 HPCSBAT0
    

Publications Referenced
SC19290500    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R110 PSY UI53222

       UP18/01/18 P F801

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 February 2018