A fix is available
APAR status
Closed as new function.
Error description
Change Accumulation JCL with SCAN mode generates JCL for a full change accum up to current time, regardless if a specific time (LOG TIME TO) is provided in the control cards. Change Accum JCL without SCAN mode and a specific time (LOG TIME TO) provided in the control cards execute the change accum JCL generated up to the specified time. We would like the SCAN mode to also generate the JCL up to the specified time period rather than up to current time. RFE 67728
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Recovery Solution Pack V1.1 * **************************************************************** * PROBLEM DESCRIPTION: REQ CA JCL GENERATED WITH SCAN MODE * * EQUAL JCL GENERATED FOR ACTUAL CA * **************************************************************** * RECOMMENDATION: * **************************************************************** Change Accumulation JCL with SCAN mode generates JCL for a full change accum up to current time, regardless if a specific time (LOG TIME TO) is provided in the control cards. Change Accum JCL without SCAN mode and a specific time (LOG TIME TO) provided in the control cards execute the change accum JCL generated up to the specified time. We would like the SCAN mode to also generate the JCL up to the specified time period rather than up to current time.
Problem conclusion
Temporary fix
Comments
Pass CATIME parameter on GENJCL.CA if LOG TIME=timestamp is specified.
APAR Information
APAR number
PI42234
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
110
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function
Submitted date
2015-06-02
Closed date
2015-10-22
Last modified date
2015-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI32317
Modules/Macros
HPCABAT0 HPCADRIV HPCAEG03 HPCAMAIN
SC19290303 |
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R110 PSY UI32317
UP15/10/28 P F510
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 November 2015