A fix is available
APAR status
Closed as program error.
Error description
A CF structure fails to recover with following messages : CSQE101I CSQ1 CSQERCFS Unable to backup or recover structure CF1,structure in use CSQ9023E CSQ1 CSQERCFS ' RECOVER CFSTRUCT' ABNORMAL COMPLETION Additional Symptom(s) Search Keyword(s):
Local fix
Restart the queue manager that attempted to recover the CF structure and is still connected to the structure. Then issue the RECOVER CFSTRUCT command for the structure on any queue manager in the QSG.
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: Auto recovery of a CF structure does * * not complete. No messages such as * * CSQE135I and CSQE131I that * * respectively show the progress of * * recovering the structure, and that * * structure recovery is complete, are * * issued for the structure in question. * * The queue manager remains connected * * to the structure and the structure * * status is INRECOVER. Attempts to * * recover the structure with the * * RECOVER CFSTRUCT command on the * * queue manager that is connected to * * the structure fail and message * * CSQE102E (structure not in failed * * state) is issued. Attempts to recover * * the structure on any other queue * * manager in the QSG fail and message * * CSQE101I (structure in use) is issued. * **************************************************************** * RECOMMENDATION: * **************************************************************** When auto recovery starts for a CF structure, CSQERCFT stores the address of the STRB for the structure being recovered before connecting to the structure. In some cases, such as when a previous recovery attempt has failed and auto recovery has been rescheduled for the structure, this STRB can be freed, and possibly reallocated for use by another structure, before it is used by CSQERCFT to locate the structure's BRCB. This can cause a failure to copy the BRCB address for the structure into the EUWH BRCB array, causing the structure to be excluded from the rest of recovery processing, including disconnecting from the structure at the end of recovery. The queue manager therefore remains connected to the structure and the structure remains in INRECOVER state.
Problem conclusion
CSQERCFT has been updated to ensure that a valid STRB address is used for each structure being recovered. 100Y CSQERCFT
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI28959
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-11-04
Closed date
2014-11-26
Last modified date
2015-02-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI29323 UI23438
Modules/Macros
CSQERCFT
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R100 PSY UI23438
UP15/01/18 P F501
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: