Troubleshooting
Problem
CNCD022E Error connecting to server Error: Connection Exception! Unexpected IOException in CommunicationBuffer::Rece
Symptom
Error when using Sterling Control Center "Test Connection" button to test connection between SCC and a C:D zOS node
SCC was specifying mainframe password in lower case. This is not converted to upper case.
Error Message29 Sep 2010 10:42:05,840 1291122 zOS.node.name(1)] DEBUG 46 - zOS.node.name: Attempting to acquire ThrottleToken()
29 Sep 2010 10:42:05,840 1291122 [zOS.node.name(1)] DEBUG 46 - zOS.node.name: Acquired ThrottleToken()
29 Sep 2010 10:42:05,840 1291122 [zOS.node.name(1)] DEBUG 46 - zOS.node.name: >>>> Signing on. Host: zOS.ip.address Apiport: zOS.port Sourceport: Protocol: TCPIP
29 Sep 2010 10:43:09,284 1354566 [zOS.node.name(1)] ERROR 46 - CNCD022E Error connecting to server. Server ID: zOS.node.nam e Host Name: zOS.ip.address API Port: zOS.port Source Port: User ID: zOS.userid Details: Error: Connection Exception! Unexpected IOException in CommunicationBuffer::Receive().
29 Sep 2010 10:43:09,284 1354566 [zOS.node.name(1)] DEBUG 46 - zOS.node.name: Attempting to release ThrottleToken()
29 Sep 2010 10:43:09,284 1354566 [zOS.node.name(1)] DEBUG 46 - zOS.node.name: Released ThrottleToken()
Resolving The Problem
Changed mainframe password specified by Sterling Control Center to upper case. Test of Connection will now work.
Historical Number
NFX9995
Product Synonym
[<p><b>]Severity[</b><p>];Normal;[<p><b>]Type[</b><p>];NormalFix
Was this topic helpful?
Document Information
Modified date:
17 December 2019
UID
swg21557775