"ERROR: Error description not implemented"  Displayed for ErrorCode="YFS10003" or "YFS10005", Though Description Present in Database

Troubleshooting


Problem

"ERROR: Error description not implemented"  Displayed for ErrorCode="YFS10003" or "YFS10005", Though Description Present in Database

Symptom

The following errors are generated by the createOrder API when trying to create an order (Note: This issue is valid only for running the Java version of Application Server (2.0-SP3) on Solaris):

<Error ErrorCode="YFS10005" ErrorDescription="Error description not implemented" ErrorRelatedMoreInfo="Insert Failed OrderNo=org.omg.CORBA.StringHolder@f27382cc Table: YFS_ORDER_HEADER" />
<Error ErrorCode="YFS10003" ErrorDescription="Error description not implemented" <br>PART: API 2.0 SP3-SUN Platform<br>COMPONENT: createOrder<br>OS: Windows NT - 4.0 SP 3<br>DATABASE: Oracle - 7.3.2<br>WEB SERVER: IIS - 3.0

Cause

Resolving The Problem

To check the correct description of errors, log in to Platform Configurator and go to "Error Assistant" screen. Search for the actual error code returned by the API. If the error description does exist in the ->Error Assistant, then do the following check:

1. Edit the weblogic.properties file in <weblogic_installation_dir>/.

2. Check if the property named "#weblogic.system.startupClass.[virtual_name]=[full_pathname]" is initialized to "com.yantra.appserver.weblogic.weblogicinitializer" class file. If not, add this entry to the weblogic.properties. A sample entry for this property is:

weblogic.system.startupClass.wlsInit=com.yantra.appserver.weblogic.we blogicinitializer

3. After saving the properties file, restart the Weblogic server.

If after implementing this solution and the problem still persists, check in the <weblogic_installation_dir>/myserver/weblogic.log file for any errors associated with invoking the startup class. If there are errors in invoking the startup class, ensure that the path to the weblogicinitializer class is correct.

If errors still persist, contact Yantra Technical Support.

[{"Product":{"code":"SS6PEW","label":"IBM Sterling Order Management"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]