Troubleshooting
Problem
Attempts to open a module results in an error when using IBM Rational DOORS" E- DXL:
Resolving The Problem
The easiest way is to go to the Rational DOORS database to conf/u1000001.dir/csint+AF8-<moduleid> and find the file that is called config.dat.
Inside the file, find this line:
csint_status=ON
Change ON to OFF, save the file, then open the module and it should not force them to read-only mode anymore. It would be a good idea at this point to delete the csint attributes in the module. Also use the Rational DOORS trigger manager DXL (get from somebody in IBM support) to delete the module open trigger.
You can get the unique ID of a module in DOORS by opening it in read-only and running the following DXL:
Module m = current
string moduleid = uniqueID(item(fullName m))
Was this topic helpful?