How To


Summary

This article is an example of Power Server Scale-Out and Enterprise Models "Adapter Hot-plugging" task. Which is the changing adapters with the server up and running workloads. The individual PCIe adapter is powered off to make a safe operation.

Objective

Nigels Banner

Steps

In the past with the POWER7 and POWER7+ based Scale-Out smaller Models, users had to shut down the whole server to add, remove, or replace an adapter safely.  In fact, some servers would power off as you removed the lid.  

The powering-off disruption is no longer needed with the whole POWER8 and POWER9 PowerVM server range including the Scale-Out Models like the S822, S824, S922, and S924.  These servers do not use the blind swap cassettes that allow the adapters to be removed from the rear of the server.  So you must use a cable management arm setup to allow the server to be pulled out at the front on the rails. Then, you raise the lid and you find there are a number of items inside with Terracotta (reddish - orange) handles. These handles can be removed with the server running.  Things like the fans and disks at the front of the server, internal I/O adapters, and power supplies at the back of the server.

BE WARNED - YOU MUST TO FOLLOW PROCEDURES ON THE HMC FIRST

These topics are covered in this article.

Note: Emily Barrett and Gareth Coates did all the work and screen captures. I (Nigel) did the editing of the results into this blog.


POWER8 Concurrent Maintenance (hot swap or hot-plug)

By Emily Barrett and Gareth Coates - EMEA Power Advanced Technology Support

In the following picture, Emily is pointing to the rear of the POWER8 server, a Model S824 and at the PCIe3 adapter that needs to be replaced. It is powered on with LED lights showing it is active.

hot plag

The previous picture (righthand side) shows the adapter slot is the label "C5".  We need this information, when we access the Hardware Management Console (HMC) as we see in the following pictures, to start a procedure on that adapter slot. 

The following pictures are from the HMC Enhanced+ graphical user interface.

image 2472

image 2474

image 2477

In the screen capture of the HMC, first the whole server is selected and then from the button the Properties pane selected, then

  1. "Processor, Memory, I/O"
  2. Click "I/O"
  3. And we can find the adapter ending in "C5" and in this case it is a "PCIe2 16 Gb 2-Port Fibre Channel Adapter"

Before we go further, the adapter has to be removed from the Logical Partition (LPAR) so that it is not active and no device drivers can be accessing it as it is being removed.  Note: a Power Server Logical Partition is the same as a Virtual Machine (VM).  In this case, the adapter is assigned to the Virtual I/O Server.  So to investigate, the padmin user of the VIOS runs the lsdev command (the output fields is limited to the needed fields). 

Log in to the VIOS as padmin user
 
  $  lsdev  -field name physloc | grep C5  fcs4             U78C9.001.WZS00DJ-P1-C5-T1  fcs5             U78C9.001.WZS00DJ-P1-C5-T2  fscsi4           U78C9.001.WZS00DJ-P1-C5-T1  fscsi5           U78C9.001.WZS00DJ-P1-C5-T2  hdisk0           U78C9.001.WZS00DJ-P1-C5-T1-W500507680210AC8C-L0  sfwcomm4         U78C9.001.WZS00DJ-P1-C5-T1-W0-L0  sfwcomm5         U78C9.001.WZS00DJ-P1-C5-T2-W0-L0

The adapter includes 2 external port, a number of device drivers running features and a Fibre Channel disk called hdisk0.

To illustrate what happens if you do not remove all these resources - let us try the HMC procedure to remove the device.

On the HMC, find the Field Replacement Unit (FRU) link.

image 2479

Whole Server view then:

  1. Serviceability
  2. Hardware
  3. Exchange FRU

Then, as in the next picture, select the main server unit (if your server includes a remote I/O drawers) in which the adapter is found (the alternative would be a Remote I/O drawer unit) and then PCI adapter:

image 2482

Then, click Next.

hp5

In the previous picture, the "C5" adapter slot position is selected and click Add.  Then, click "Launch Procedure"

hp6

The HMC pane asks, do you want to do the operation now or later? Then, it wants you to check whether any LPAR involved is running Linux - in this case it is the Virtual I/O Server (VIOS), so the answer is "no" then, click Next.

In the following picture the HMC determines the PCIe3 adapter is still in use and needs you do fix that before proceeding:

hp7

So next we go back to the VIOS and remove all the devices. This mechanism stops the VIOS from trying to use the device while or during the time the adapter is removed or a replacement is in the adapter slot.

 On the VIOS LPAR

  $ lspath  status  name   parent connection    Enabled hdisk0 fscsi0 500507680210ac8c,0  Enabled hdisk0 fscsi0 500507680220ac8c,0  Enabled hdisk0 fscsi4 500507680210ac8c,0  Enabled hdisk0 fscsi4 500507680220ac8c,0  $  $  $ rmdev -dev fcs4 -recursive  sfwcomm4 deleted  fscsi4 deleted  fcs4 deleted  $  $ rmdev -dev fcs5 -recursive  sfwcomm5 deleted  fscsi5 deleted  fcs5 deleted  $
 The -recursive option makes sure that all related resources are also removed.

hp8

We return to the HMC, select the "Try Again" is selected and click Next.  Read the two warning and information panes ...

hp9

Making sure we change the correct adapter in the correct server.

The following picture shows the HMC via the service processor switches on the Identify LED at both the Server front "Ops Pane" and the read adapter slot.

hp10

Important: Imagine a computer room with twenty racks of identical servers, it would be simple to go to the wrong rack, server, or adapter slot, so it is a good safety double check.

Next, we return to the HMC it wants to check the adapter width (single or double width).  Double width adapters are rare.  I guess it would want to power down both slots.  So select "single slot" and Next.

hp11

Then, the HMC gives you plenty of diagrams to find the correct adapter slot and how to unscrew the server and pull it out on the rails.

If you are sure you know the adapter slot and how to do that - click Next repeatedly to go through them, quickly:

hp13

Opening the box

hp14

So Emily gets busy with the screwdriver, releases the server, and slides it out on the rails.  I assumes the cable management arm is fitted at the back of the server and ALL that cables are using the arm.

It is worth checking the cabling, before pulling out the POWER8 server at the front and breaking all the cables or damage an adapter!
Nigel added: In the past, I've broken cables and you feel such an idiot afterward. The guys refused for years to let me move any RBG video screen!

hp15

The HMC then informs you how to release and remove the server lid:
hp16
You guessed it!  Emily does the same in the following picture and we can see the light path LED lit up next to the adapter.  It would be a shame to yank out the wrong one out!   Note the LED is a triangle "arrow" pointing at the adapter.
hp17

Removing the adapter

On the HMC, the following picture, it describes how to remove the adapter:

hp18
Oddly the diagram is removing the adapter from the same adapter slot as Emily.  This coincidence is a nice touch from the hardware documentation editors.  The picture shows a white click to release but it is really Red / Orange in colour. Emily carefully removes the adapter.  This server is not a $10 PC Ethernet NIC adapter but a rather expensive super fast enterprise-level adapter so treat it with care.  You can't quite see it but near Emily's elbow she is wearing an approved electrostatic earth strap that is also clipped to the frame of the rack.
hp19

At last, the job is done - - - well - - - not quite.  This task is to replace the adapter with another one (you might guess we are going to put the same adapter back in the slot for this practice run).  Alternative tasks are"Add Adapter" or a "Remove Adapter" but I hope you get the idea.

 Finishing off

The HMC informs you how to finish off using the reverse procedure:

hp20
hp21
hp22
Emily points out the blue little arm clips you raise to release the drawer so it can be slid back into the rack, in following pictures and the adapter is showing LEDs.
hp23
In the following pictures, the HMC plays it safe and waits a bit to let the adapter power on and completes the initialisation functions.
hp24
If we are happy, we can close the "Replace Hardware" Task as in the following pictures:
hp25

Back on the Operating System, here the VIOS, we tell it to investigate its buses for new I/O adapters.
Note: the AIX the command is "cfgmgr" and on Linux it is more complicated (IMHO), so check you Linux documentation.

 Back on the VIOS as the padmin user  

  $ cfgdev     $ lspath     status  name   parent connection   Enabled hdisk0 fscsi0 500507680210ac8c,0   Enabled hdisk0 fscsi0 500507680220ac8c,0   Enabled hdisk0 fscsi4 500507680210ac8c,0   Enabled hdisk0 fscsi4 500507680220ac8c,0   $
The adapter and associated devices are ready to use again.  Once you perform this or similar tasks a few of times, it is very simple to follow but the HMC does guide you and makes sure you don't miss a step.

- - - The End - - -

    Additional Information


    Other places to find content from Nigel Griffiths IBM (retired)

    Document Location

    Worldwide

    [{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG10","label":"AIX"},"Component":"","Platform":[{"code":"PF002","label":"AIX"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HW1W1","label":"Power -\u003EPowerLinux"},"Component":"","Platform":[{"code":"PF016","label":"Linux"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Component":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]