IBM Support

Event log does not show triggered events when thresholds are exceeded

News


Abstract

Event log does not show triggered events when thresholds are exceeded

Content

You are in: IBM i Technology Updates  > IBM Navigator for i > Enhancements list > Monitors > Event log does not show triggered events when thresholds are exceeded

If you are having a problem with triggered events not showing up in the Monitor event log, restart the Monitor job.  Especially if you can see instances that the threshold is exceeded, but no trigger is occurring. 

First, end the monitor server with:

    > CALL PGM(QSYSDIR/QNAVMNSRV) PARM(*STOP) - New IBM Navigator for i Monitor

    CALL PGM(QSYSDIR/QINAVMNSRV) PARM(*STOP) - heritage Navigator Monitor

Then, end and restart the ADMIN1 server:

    > ENDTCPSVR SERVER(*IAS) INSTANCE(ADMIN1)

    > STRTCPSVR SERVER(*IAS) INSTANCE(ADMIN1)

Monitors might not be triggered correctly if the IBM Navigator PTF is installed without first stopping the Monitor job.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Component":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
06 June 2022

UID

ibm11164706