Troubleshooting
Problem
On N6200 Series systems, when the NVMEM battery reaches the critical low capacity level of 72-hr run-time, the system will initiate a 24-hr shutdown sequence. This technote describes how to determine the Fast Charge Mode Time Out (FCMTO) problem and instructions on how to download and install stand-alone battery firmeware which fixes this issue. Service Processor firmware version 1.3 now includes the battery firmware and is the preferred method to install.
Symptom
There are several ways this issue can manifest, including warning and critical system notifications, depending on the battery charge level.
- Warning low limit exceeded 80-hr run-time:BATT_CAP_LOW
Sun Nov 20 00:00:11 CET [befiler04:nvmem.battery.capacity.low.warn:info]: The NVMEM battery capacity is below normal. - Critical low limit exceeded 72-hr run-time: LOW_BATT
Mon Nov 21 20:00:00 CET [befiler04: monitor.nvramLowBattery:CRITICAL]: NVRAM battery is dangerously low.
Mon Nov 21 20:00:00 CET [befiler04: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down. (The 24 hour timeout may be increased by altering the "raid.timeout" value using the "options" command.
Mon Nov 21 20:00:00 CET [befiler04: monitor.shutdown.nvramLowBattery.pending:warning]: NVRAM battery is dangerously low. Halting system in 24 hours. Replace the battery immediately!
Mon Nov 21 20:00:00 CET [befiler04: asup.throttle.drop:info]: Too many autosupport messages in too short a time, throttling autosupport: BATTERY_LOW
Cause
This message is sent as long as the battery is below the minimum safe voltage required to protect the data in the event of a power failure or unexpected shutdown.
Environment
Scope of Affected Systems: Deliveries for all N6200 series (N6210, N6240 and N6270) filer and gateway systems prior to March 2012 contain battery firmware which is susceptible to the FCMTO issue.
Diagnosing The Problem
AutoSupport Verification of the Issue
Charger Volt normal 0 mV -- -- 8900 mV 9000 mV
Charger Cycles normal 0 cycles -- -- 250 cycles 251 cycles
Charger Curr normal 0 mA -- -- 2200 mA 2300 mA
Bat Temp normal 20 C -40 C 1 C 70 C 75 C
Bat Run Time warnlow 80 hr 72 hr 80 hr -- --
Bat Capacity normal 3072 mA*hr -- -- -- --
Bat Curr normal 0 mA -- -- 2048 mA 2304 mA
Bat 8.0V normal 7400 mV -- -- 8900 mV 9000 mV
Bat 1.8V normal 1818 mV 1612 mV 1625 mV 1973 mV 1999 mV
AutoSupport (ASUP) messages from a system can be reviewed to determine the status of the NVMEM battery related to this issue:
- If the system has detected a ‘warning low’ or ‘critical low battery’ condition, the ENVIRONMENT section of the system ASUP will contain battery sensor details.
- A symptom for this issue can be either that the run-time is less than ‘80-hr Warning’ or less than ‘72-hr Critical’. Systems above 80 hrs run-time will not produce a message.
- Another symptom is that the “Bat Curr” = 0mA. The charger should be on based on the low capacity level of the battery, and this sensor confirms that there is no current going into the battery.
- The last symptom for this issue is that ”Charger Volt” displays 0V. In normal operation, it should always be reported as 8200 mV.
Charger Volt normal 0 mV -- -- 8900 mV 9000 mV
Charger Cycles normal 0 cycles -- -- 250 cycles 251 cycles
Charger Curr normal 0 mA -- -- 2200 mA 2300 mA
Bat Temp normal 20 C -40 C 1 C 70 C 75 C
Bat Run Time warnlow 80 hr 72 hr 80 hr -- --
Bat Capacity normal 3072 mA*hr -- -- -- --
Bat Curr normal 0 mA -- -- 2048 mA 2304 mA
Bat 8.0V normal 7400 mV -- -- 8900 mV 9000 mV
Bat 1.8V normal 1818 mV 1612 mV 1625 mV 1973 mV 1999 mV
Sometimes, the only information provided in the ENVIRONMENT section of the ASUP is:
Battery: Sensor Bat_Run_Time warning low: current custom is 74 , critical low is 72 , normal low is 80
Systems not on AutoSupport can be interrogated using the SP command system sensors. The details can be found in the procedure provided.
Resolving The Problem
Solution
This technote describes how to obtain and apply the stand-alone battery firmware, however, the battery firmware is available as a part of Service Processor firmware version 1.3 and is the preferred method to install. See the Service Processor (SP) Firmware for N series Publication Matrix (S7003683) technote for more information on how to obtain and install Service Processor firmware.
The system battery firmware revision should be identified to confirm if a firmware update is required. Follow steps 1-5 of the section How to flash the battery Firmware to confirm if an update to the battery firmware is required.
There are two parts to this procedure, Flashing the Battery Firmware and Resetting the FCMTO flag. The FCMTO flag issue can be confirmed by following steps 1-5 of the Resetting the FCMTO flag procedure. For systems which have not encountered the FCMTO flag issue, there is no need to perform the Resetting the FCMTO flag procedure. There are two scenarios for the systems:
Note: Flashing the battery firmware does not clear the FCMTO flag.
Notes:
How to obtain the Battery Firmware
The Battery Firmware is installed on your N series hardware and is available for download using the "Software Packages ...." link from the Download page of the N series support website. Refer to the important information for N series support for step-by-step instructions explaining how to access software packages as part of the complete instructions for entitlement and registration. When following the step-by-step instructions, select the Service Processor (SP) Firmware software package from the N series and related Host Software Downloads - Pick page. Download the Stand-alone Battery Firmware for N6200 series file (battery-27100027-ifiles.zip) and using the instructions below to save the two Battery Firmware Files: ‘battery-27100027-nexergy.i’ and ‘battery-27100027-energysales.i’ to the <Battery_Firmware_File_Location>, identified on the user’s Web server.
Important: A N6200 series system with network connectivity through the SP port is required. A Web server is also required to apply the battery firmware update.
Download the updated firmware, extract the files from the archive, and place the files on a Web server in a subnet that is accessible by the Service Processor. We will refer to this location as <Battery_Firmware_File_Location>. This URL location must be less than 100 characters.
How to enable the SP port (if not currently set up)
Perform the following steps:
1. Connect a network cable to the N6200 system SP port.
2. Setup the SP with a static IP address:
How to flash the battery Firmware
1. Use the following command to halt the system.
2. Log in to the SP CLI by using control+G:
3. Login as naroot. Input a password if necessary.
4. Enable diagnostic privileges and display the battery information:
5. Confirm the battery vendor (EnergySales,or Nexergy) and check the rev_hardware values. If the rev_hardware is 0x00d3 or higher, the battery firmware already has the FCMTO related change. In this case, do not upgrade the battery firmware as the these batteries are already updated (you will be prompted with 'are you sure you want to update?' ).
6. Flash the battery firmware on to the battery. Use the correct battery firmware file: ‘battery-27100027-nexergy.i’ or ‘battery-27100027-energysales.i’ depending on the manufacturer identified in step 5. A confirmation 'Battery firmware update completed.' will be displayed on successful completion of the operation.
7. Perform a battery verify. A 'Verify test passed' message will be displayed on successful completion of the operation.
8. Verify the rev_hardware has changed to 0x00d3.
9. Exit the SP shell, (if SSH was used to access the SP, connect to the system console port).
SP*>CTRL-D to exit SP shell
10. Boot ONTAP:
Resetting the FCMTO flag
1. Enter the SP shell:
2. Run the following command from the system console port:
3. Check if “Bat_Run_Time” is below 80-hr Warning or below 72-hr Critical.
4. Confirm that “Bat_Curr” = 0 mA and “Charger_Volt” = 0 mV.
5. Press CTRL-D to exit the SP shell (if SSH was used to access the SP, connect to the system console port).
6. Use the following command to halt the system.
7. Enter Maintenance Mode. While booting Data ONTAP when the CTL-C message appears, press <CTL-C> to interrupt the boot process
8. Clear the “no charger” condition by running the following command:
10. Enter the SP shell, as indicated in step 2.
11. Confirm the battery status by running the system sensors command, as indicated in step 2.
12. Verify that “Charger_Volt” is 8200 mV and there is “Bat_Curr” >0 mA (if the battery needs to be charged). If the battery is fully charged, Bat_Curr will be 0mA and “Charger_Volt” will be 8.200 V. Recheck “Bat_Run_Time”. This value should be increasing. For systems which did not reach 72 hr “runtime” threshold, the battery should recover and the warning messages will discontinue.
13. Press CTRL-D to exit the SP shell (if SSH was used to access the SP, connect to the system console port).
Related Links
This technote describes how to obtain and apply the stand-alone battery firmware, however, the battery firmware is available as a part of Service Processor firmware version 1.3 and is the preferred method to install. See the Service Processor (SP) Firmware for N series Publication Matrix (S7003683) technote for more information on how to obtain and install Service Processor firmware.
The system battery firmware revision should be identified to confirm if a firmware update is required. Follow steps 1-5 of the section How to flash the battery Firmware to confirm if an update to the battery firmware is required.
There are two parts to this procedure, Flashing the Battery Firmware and Resetting the FCMTO flag. The FCMTO flag issue can be confirmed by following steps 1-5 of the Resetting the FCMTO flag procedure. For systems which have not encountered the FCMTO flag issue, there is no need to perform the Resetting the FCMTO flag procedure. There are two scenarios for the systems:
Note: Flashing the battery firmware does not clear the FCMTO flag.
- Systems which have the FCMTO flag set condition:
Actions: Flash the battery Firmware and Reset the FCMTO flag - Systems which do not have the FCMTO flag issue:
Actions: Verify the FCMTO flag issue is not present in the system and flash the battery firmware
Notes:
- The battery firmware update must be performed prior to resetting the FCMTO flag.
- This is a disruptive procedure and will require system downtime.
- For HA systems, a takeover and giveback should be managed in conjunction with the system halt required for this procedure, and this might reduce the operational impact of this procedure for some users.
How to obtain the Battery Firmware
The Battery Firmware is installed on your N series hardware and is available for download using the "Software Packages ...." link from the Download page of the N series support website. Refer to the important information for N series support for step-by-step instructions explaining how to access software packages as part of the complete instructions for entitlement and registration. When following the step-by-step instructions, select the Service Processor (SP) Firmware software package from the N series and related Host Software Downloads - Pick page. Download the Stand-alone Battery Firmware for N6200 series file (battery-27100027-ifiles.zip) and using the instructions below to save the two Battery Firmware Files: ‘battery-27100027-nexergy.i’ and ‘battery-27100027-energysales.i’ to the <Battery_Firmware_File_Location>, identified on the user’s Web server.
Important: A N6200 series system with network connectivity through the SP port is required. A Web server is also required to apply the battery firmware update.
Download the updated firmware, extract the files from the archive, and place the files on a Web server in a subnet that is accessible by the Service Processor. We will refer to this location as <Battery_Firmware_File_Location>. This URL location must be less than 100 characters.
How to enable the SP port (if not currently set up)
Perform the following steps:
1. Connect a network cable to the N6200 system SP port.
2. Setup the SP with a static IP address:
- LOAD-A> sp setup
The Service Processor (SP) provides remote management capabilities including console redirection, logging and power control.
It also extends autosupport by sending additional system event alerts. Your autosupport settings are used for sending these alerts via email over the SP LAN interface.
Would you like to configure the SP? yes
Would you like to enable DHCP on the SP LAN interface? no
Please enter the IP address for the SP [ ]: 192.168.30.243
Please enter the netmask for the SP [ ]:255.255.254.0
Please enter the IP address for the SP gateway []:192.168.30.1
Do you want to enable IPv6 on the SP ? no
How to flash the battery Firmware
1. Use the following command to halt the system.
- ontap> halt
1a. Alternatively, a 'cf takeover' can be executed from the partner node in a clustered configuration.- From the partner controller issue the following command:
However, before running the command, ensure that autogiveback is not enabled (that is, ON).
ontap> options cf.giveback.auto.enable
If enabled:
ontap> options cf.giveback.auto.enable off
partner_ontap> cf takeover
1b. If AUTOBOOT environment variable is set to TRUE, the local node boots to- ' Waiting for giveback...(Press Ctrl-C to abort wait)' prompt.
Use control+c to abort waiting and halt the node. Enter 'y' when the system prompts:
Do you wish to halt this node rather than wait [y/n]?
- From the partner controller issue the following command:
2. Log in to the SP CLI by using control+G:
- LOADER> CTRL+G
3. Login as naroot. Input a password if necessary.
- Switching console to Service Processor
Service Processor Login: naroot
4. Enable diagnostic privileges and display the battery information:
- SP>priv set diag
5. Confirm the battery vendor (EnergySales,or Nexergy) and check the rev_hardware values. If the rev_hardware is 0x00d3 or higher, the battery firmware already has the FCMTO related change. In this case, do not upgrade the battery firmware as the these batteries are already updated (you will be prompted with 'are you sure you want to update?' ).
- SP*>system battery show
chemistry : LION
device-name : bq20z80
expected-load-mw : 90
id : 27100027
manufacturer : EnergySales
manufacturer-date : 4/4/2010
rev_cell : 0x0000
rev_firmware : 0x0100
rev_hardware : 0x00d1
TI_fw_version : 0x0102
TI_hw_version : 0xa2
serial : 0x0001
status : ready
6. Flash the battery firmware on to the battery. Use the correct battery firmware file: ‘battery-27100027-nexergy.i’ or ‘battery-27100027-energysales.i’ depending on the manufacturer identified in step 5. A confirmation 'Battery firmware update completed.' will be displayed on successful completion of the operation.
- For Energy Sales Batteries:
SP*> system battery flash http://<Battery_Firmware_File_Location>battery-27100027-energysales.i
-OR-
For Nexergy Batteries:
SP*> system battery flash http://<Battery_Firmware_File_Location>battery-27100027-nexergy.i
Downloading battery firmware image ... Successful
Accessing battery ...
Flashing 27100027-EnergySales battery FW revision from 'd1' to 'd3' ... done
Disabled battery auto update after manual firmware flash
Battery firmware update completed.
7. Perform a battery verify. A 'Verify test passed' message will be displayed on successful completion of the operation.
- For Energy Sales Batteries:
SP*> system battery verify http://<Battery_Firmware_File_Location>battery-27100027-energysales.i- -OR-
For Nexergy Batteries:
SP*> system battery verify http://<Battery_Firmware_File_Location>battery-27100027-nexergy.i
Downloading battery firmware image ... Successful
Verify test passed
8. Verify the rev_hardware has changed to 0x00d3.
- SP*> system battery show
chemistry : LION
device-name : bq20z80
expected-load-mw : 90
id : 27100027
manufacturer : EnergySales
manufacturer-date : 4/4/2010
rev_cell : 0x0000
rev_firmware : 0x0100
rev_hardware : 0x00d3
TI_fw_version : 0x0102
TI_hw_version : 0xa2
serial : 0x0001
status : ready
9. Exit the SP shell, (if SSH was used to access the SP, connect to the system console port).
SP*>CTRL-D to exit SP shell
10. Boot ONTAP:
- LOADER> boot_ontap
10a. On a cluster system, when the node boots to the 'Waiting for giveback...(Press Ctrl-C to abort wait)' prompt, perform a giveback from the partner node:
Partner_ontap> cf giveback
Resetting the FCMTO flag
1. Enter the SP shell:
- ONTAP> CTRL-G
2. Run the following command from the system console port:
- Login naroot
Enter password if required
Display the sensor information by running the following command:
SP*> system sensors
Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
---------------+---------+-------------+--------+---------+----------+---------+---------
Bat_1.8V | 1.819 | Volts | ok | 1.613 | 1.625 | 1.974 | 2.000
Bat_8.0V | 8.100 | Volts | ok | na | na | 8.900 | 9.000
Bat_Curr | 0.000 | Amps | ok | na | na | 2.048 | 2.304
Bat_Capacity | 3.840 | Amps * hour | ok | na | na | na | na
Bat_Run_Time | 80.00 | hour crit | 72.000 | 80.000 | na | na
Bat_Temp | 21.000 | degrees C | ok | -40.000 | 1.000 | 70.000 | 75.000
Charger_Curr | 0.000 | Amps | ok | na | na | 2.200 | 2.300
Charger_Cycles | 0.000 | cycles | ok | na | na | 250.000 | 251.000
Charger_Volt | 0.000 | Volts | ok | na | na | 8.900 | 9.000
2a. Optional method to access the SP shell: Use SSH to the SP interface to get to the SP CLI for issuing commands.
3. Check if “Bat_Run_Time” is below 80-hr Warning or below 72-hr Critical.
4. Confirm that “Bat_Curr” = 0 mA and “Charger_Volt” = 0 mV.
- For systems below 72-hr Critical Low threshold – LOW_BATT, take immediate action. The shutdown sequence has begun.
For systems below 80-hr but > 72-hr “run time,” there is some time prior to initiating the shutdown sequence. Under normal conditions, a typical battery can take up to 14 days to decrease from 80 to 72-hr “run time.”
5. Press CTRL-D to exit the SP shell (if SSH was used to access the SP, connect to the system console port).
- ***Proceed with the following steps during a scheduled maintenance window***
6. Use the following command to halt the system.
- ontap> halt
- 6a. Alternatively, a 'cf takeover' can be executed from the partner node in a clustered configuration. From the partner controller, run the following command.
However, before doing that, ensure autogiveback is not enabled (that is, ON).
ontap> options cf.giveback.auto.enable
If enabled:
ontap> options cf.giveback.auto.enable off
partner_ontap> cf takeover
6b. If the AUTOBOOT environment variable was set to TRUE, the local node boots to the ' Waiting for giveback...(Press Ctrl-C to abort wait) ' prompt.
Press control+c to abort waiting and halt the node. Enter 'y' when the system prompts 'Do you wish to halt this node rather than wait [y/n]?'.
7. Enter Maintenance Mode. While booting Data ONTAP when the CTL-C message appears, press <CTL-C> to interrupt the boot process
- LOADER> boot_ontap
Select '5' as the Maintenance Mode boot method.
8. Clear the “no charger” condition by running the following command:
- *> halt
- LOADER> boot_ontap
For systems with less than 72 hr “runtime,” the system will not boot Data ONTAP until the battery has charged to a minimum of 72 hr “runtime” is reached. This is usually achieved in a few minutes, the command CTRL+G could be used to bypass the wait period depending on the customer environment..
Note: If the wait period is bypassed the warning messages will continue until the battery is sufficiently charged beyond the 72 hour threshold.
9a. If a takeover was performed per step 6a, the controller will boot to 'waiting for giveback'. From the partner controller issue the following command.
Partner_ontap> cf giveback
10. Enter the SP shell, as indicated in step 2.
11. Confirm the battery status by running the system sensors command, as indicated in step 2.
12. Verify that “Charger_Volt” is 8200 mV and there is “Bat_Curr” >0 mA (if the battery needs to be charged). If the battery is fully charged, Bat_Curr will be 0mA and “Charger_Volt” will be 8.200 V. Recheck “Bat_Run_Time”. This value should be increasing. For systems which did not reach 72 hr “runtime” threshold, the battery should recover and the warning messages will discontinue.
13. Press CTRL-D to exit the SP shell (if SSH was used to access the SP, connect to the system console port).
Related Links
- Technote N6200 series critical battery firmware update available that eliminates battery FCMTO error condition (S1004007) - overview alert of issue.
- Technote N6200 series system warning message: NVMEM battery is low on power and should be replaced as soon as practical (S1003985) - includes temporary workaround until battery firmware can be applied.