IBM Support

KFASD007 Detected failure STATE <ME>, STATUS <1007>, SEEDSTATE < >, in a prior VERSION

How To


Summary

z/OS based TEMS may produce error message KFASD007 indicating that a problem occurred previously when trying to install the Self Describing Agent for a specific product.

Objective

This setting within the TEMS must be cleared before a new attempt can be made to install the affected product's SDA.

Environment

z/OS based TEMS and OMEGAMON Agents

Steps

  1. Determine what prevented the original attempt to install SDA for this product. Typical reason may include lack of RACF authority to USS tables where this data is stored.
  2. Determine the RKANSQLU dataset name within the affected TEMS's JCL.
  3. Create RKANSQLU(EDITSDA) and paste into it:
    INSERT INTO O4SRV.TAPPLPROPS (GRPID, PRODUCT, ID, CONFIG) VALUES ('5530', '*A' , 'INSTALL', 'SDA_INSTALL=ON;');
  4. Save the updated EDITSDA member
  5. Instruct the affected TEMS to execute that SQL command via a z/OS console command:
    /F temsstcname,CTDS START SPUFIL EDITSDA
  6. Check for any error messages

Document Location

Worldwide

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVT4","label":"IBM Tivoli Management Services on z\/OS"},"ARM Category":[{"code":"a8m0z0000001iEtAAI","label":"Tivoli Monitoring Services on z\/OS"}],"ARM Case Number":"TS004217577","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"All Version(s)"}]

Document Information

Modified date:
30 August 2023

UID

ibm16334767