To help you install the interim fix for IBM Maximo Anywhere 7.6.2, you can use the following installation information:

Content

----------------------------------------------------------------------------------
Obtain the interim fix
------------------------------------------------------------------------------------

Contact IBM Software Support for information about upgrades for Maximo Anywhere and how to obtain
this interim fix.

----------------------------------------------------------------------------------
Pre-installation steps
----------------------------------------------------------------------------------
Before proceeding, make a complete backup of the following folders. Default folder locations are provided below.

Maximo Admin Workstation: /IBM/SMP
Maximo Anywhere Build Server: /IBM/Anywhere

Also, make a complete backup of the Maximo database instance.
Check and record any custom WebSphere Application Server configurations, such as module bindings, virtual hosts, and environment property settings.

----------------------------------------------------------------------------------
Update the IBM Maximo Asset Management environment
----------------------------------------------------------------------------------

1. Download and extract the oslcos_pmp_deploy_latest.zip and anywhereadmin_pmp_deploy_latest.zip files to the ../IBM/SMP/maximo directory.

2. Update the database and build and deploy the EAR file, according to your version of Maximo Asset Management:

- On Maximo Asset Management 7.5.0.6 or greater, run the updatedb command in the ../IBM/SMP/maximo/tools/maximo directory. Build and deploy the EAR file.

- On Maximo Asset Management 7.6 or greater, from the Tivoli's process automation suite configuration tool, run the Update Database and Build and Deploy Application EAR Files option.

---------------------------------------------------------------------------------
Install the apps
---------------------------------------------------------------------------------

To install the apps, complete the following steps:

1. Download and extract the platform-Latest.delta.zip file to the <install_home>/MaximoAnywhere/platform directory.

2. On Windows and Linux, extract the MaximoAnywhere_7.6.2.0.latest.delta.zip to the <install_home>/MaximoAnywhere directory. Overwrite the existing MaximoAnywhere directory.

For Mac OS x systems, extract the file to a different location. Do not use Finder to overwrite the existing MaximoAnywhere directory. Instead, in a terminal, use ditto and run the following command: ditto <from_folder> <destination_folder>.

3. Extract the MaximoAnywhere/build/config/app_artifacts_previous.zip file into the MaximoAnywhere/apps path.

4. Run the following command to upgrade your WorkExecution.xml file to the latest version:

ant -f app-sparse-xml-processor.xml upgrade-previous-release-app-artifacts

5. Run the anywhere-rdfs-puller.xml file that is in the MaximoAnywhere directory.

6. If you are building Android apps, update your build.properties property to specify the version of the Android SDK that you are using, for example, Android_TARGET_DEVICE_NAME=android-23. Also, you must download the same Android SDK in your Android SDK Manager. Android 23 SDK is the minimum supported version for Android 7 apps. Otherwise, Android 21 SDK is the minimum supported version.

7. For Windows, run the following command:

build.cmd clean update-platform all

For Mac OS X, run the following command:

./build.sh clean update-platform all

----------------------------------------------------------------------------------
Post-installation steps
----------------------------------------------------------------------------------

If you have customized your Maximo Object Structures rerun the OSLC RDF Puller to pull the latest OSLC RDF documents:

https://www.ibm.com/support/knowledgecenter/SSPJLC_7.6.2/com.ibm.si.mpl.doc/integration/t_import_resource_data.html

Reapply any changes you might have made to the app-feature.properties file to reenable any custom properties you might have changed.
 
Verifying that your local customizations still exist:

Run a comparison tool like Beyond Compare to compare your backed up directory to the newly updated one.

Verify that any (class files, device native code or javascript) customizations you have made are still in place, and reapply them if not.

Verify that your app.xml file changes are still there.

Verify that the bundleids in your application-description.xml file are correct.
Verify that any custom WebSphere Application Server configurations, such as module bindings, virtual hosts, and environment property settings are still there.

If you have customized the logos on the login screen or any of the platform XML files, you must manually reapply those changes.

---------------------------------------------------------------------------------
Troubleshooting
---------------------------------------------------------------------------------

On environments without Maximo Spatial installed and the map.enabled property set to true, the build fails. Follow the instructions in the following technote to resolve this issue:

http://www.ibm.com/support/docview.wss?uid=swg22007684

---------------------------------------------------------------------------------
Android 7 support and resolved issues
---------------------------------------------------------------------------------

Maximo Anywhere now supports Android 4, 5, 6, and 7 operating systems. You can run the apps on Android 7, but you cannot yet build and deploy the apps with this version. You must apply the following interim fix for MobileFirst compatibility with Android 7, IBM MobileFirst Platform 7.1.0.00.20170505-1403.

The following issues are resolved in the Maximo Anywhere 7.6.2 interim fix:

IV93425 - 401 UNAUTHORIZED LOGIN ERROR WHEN F5 LOAD BALANCING
IV97392 - REQUIRED FIELDS IGNORED ON NEW WORK ORDER VIEW
IV96847 - CREW UTC TIMEZONE ISSUE
IV96780 - WHEN ENTERING MULTIPLE METER READINGS ONLY THE LAST READING IS SYNCHRONIZED
IV96735 - BUILD FAIL PACKAGEAPPLICATION XCODE 8.3.2
IV27116 - Get error when starting timer when System Timer setting is set to change status to INPROG
IV95966 - ANYWHERE AS FOUND STATUSES SHOWS PASSED BUT THE CALIBRATION POINT ENTRY WAS FAIL FOR COMMA BASE LOCALE
IV95189 - MAXIMO ANYWHERE NOT PROPERLY VALIDATING CERTAIN FIELD DATA WHEN ATTEMPTING TO RESEND
IV93921 - DATE ISSUE IN ACTUAL LABOR
IV91238 - On fast devices, loading message doesn't go away when viewing settings menu

[{"Product":{"code":"SSPJLC","label":"Maximo Anywhere"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"--","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]