PACKAGE: Update Release 2.2.4.20
IOSLEVEL: 2.2.4.20

VIOS level is NIM Master level must be equal to or higher than
Update Release 2.2.4.20 AIX 6100-09-07 or AIX 7100-04-02

In June 2015, VIOS introduces the minipack as a new service stream delivery vehicle as well as a change to the VIOS fix level numbering scheme. The VIOS "fix level" (the 4th number) has changed to two digits. For example, VIOS 2.2.4.2 has been changed to VIOS 2.2.4.20. Please refer to the VIOS Maintenance Strategy here for more details regarding the change to the VIOS release numbering scheme.

General package notes

Review the list of fixes included in Update Release 2.2.4.20.

To take full advantage of all the function available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 2.2.4.20.

Microcode or system firmware downloads for Power Systems

The VIOS Update Release 2.2.4.20 includes the IVM code, but it will not be enabled on HMC-managed systems. Update Release 2.2.4.20, like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS.

Update Release 2.2.4.20 updates your VIOS partition to ioslevel 2.2.4.20. To determine if Update Release 2.2.4.20 is already installed, run the following command from the VIOS command line:

$ ioslevel

If Update Release 2.2.4.20 is installed, the command output is 2.2.4.20.

Known Capabilities and Limitations

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

 

Limitations for Shared Storage Pool

Software Installation

SSP Configuration
Feature Min Max
Number of VIOS Nodes in Cluster 1 16
Number of Physical Disks in Pool 1 1024
Number of Virtual Disks (LUs) Mappings in Pool 1 8192
Number of Client LPARs per VIOS node 1 200
Capacity of Physical Disks in Pool 10GB 16TB
Storage Capacity of Storage Pool 10GB 512TB
Capacity of a Virtual Disk (LU) in Pool 1GB 4TB
Number of Repository Disks 1 1
Capacity of Repository Disk 512MB 1016GB
 
Network Configuration
Storage Configuration
Shared Storage Pool capabilities and limitations

Installation information

Pre-installation information and instructions

Please ensure that your rootvg contains at least 30GB and that there is at least 4GB free space before you attempt to update to Update Release 2.2.4.20. Run the lsvg rootvg command, and then ensure there is enough free space.

Example:

$ lsvg rootvg 
VOLUME GROUP:       rootvg                   VG IDENTIFIER:  00f6004600004c000000014306a3db3d
VG STATE:           active                   PP SIZE:        64 megabyte(s)
VG PERMISSION:      read/write               TOTAL PPs:      511 (32704 megabytes)
MAX LVs:            256                      FREE PPs:       64 (4096 megabytes)

LVs:                14                       USED PPs:       447 (28608 megabytes)
OPEN LVs:           12                       QUORUM:         2 (Enabled)
TOTAL PVs:          1                        VG DESCRIPTORS: 2
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:         1                        AUTO ON:        yes
MAX PPs per VG:     32512                                     
MAX PPs per PV:     1016                     MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                       BB POLICY:      relocatable 
PV RESTRICTION:     none                     INFINITE RETRY: no

Upgrading from VIOS version lower than 2.1.0

If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version 2.1.0 using the Migration DVD. After the VIOS is at version 2.1.0, the Update/Fixpack 2.2.4.10 must be applied to bring the VIOS to the latest Fix Pack VIOS 2.2.4.10 level. The Update Release 2.2.4.20 can then be applied to bring the VIOS to the latest level.

Note that with this Update Release 2.2.4.20, a single boot alternative to this multiple step process is available to NIM users. NIM users can update by creating a single, merged lpp_source that combines the contents of the Migration DVD with the contents of this Update Release 2.2.4.20.

A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding, described here under "Migration DVD":

Instructions to disable Processor Folding are detailed at the link below.
See the "Migration DVD" section:

Upgrading from VIOS version 2.1.0 and above

VIOS Update Release 2.2.4.20 may be applied to VIOS level between 2.2.4.0 and 2.2.4.10. When the Single Step update procedure is used the current level of VIOS must be between 2.2.1.1 and 2.2.3.x.

NOTE: In order to update to Update Release 2.2.4.20 from a level between 2.2.1.1 and 2.2.3.x in a single step, you can put the 2.2.4.10 updates in the same location and do the update using the updateios command.

 

Before installing the VIOS Update Release 2.2.4.20

The update could fail if there is a loaded media repository.

Checking for a loaded media repository

To check for a loaded media repository, and then unload it, follow these steps.

  1. To check for loaded images, run the following command:

    $ lsvopt
    The Media column lists any loaded media.

  2. To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

    $ unloadopt -vtd <file-backed_virtual_optical_device >

  3. To verify that all media are unloaded, run the following command again.

    $ lsvopt
    The command output should show No Media for all VTDs.

Migrate Shared Storage Pool Configuration

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 2.2.4.20 using rolling updates.

If your current VIOS is running with Shared Storage Pool from 2.2.1.1 or 2.2.1.3, the following information applies:

A cluster that is created and configured on VIOS Version 2.2.1.1 or 2.2.1.3 must be migrated to version 2.2.1.4 or 2.2.1.5 prior to utilizing rolling updates. This allows the user to keep their shared storage pool devices. When VIOS version is equal or greater than 2.2.1.4 and less than 2.2.4.10, the user needs to download 2.2.4.10 and 2.2.4.20 update images into a directory, then update the VIOS to Update Release 2.2.4.20 using rolling updates.

If your current VIOS is configured with Shared Storage Pool from 2.2.1.4 or later, the following information applies:

The rolling updates enhancement allows the user to apply Update Release 2.2.4.20 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

The VIOS SSP software monitors node status and will automatically upgrade the cluster to make use of the new capabilities when all the nodes in the cluster have been updated, "cluster -status -verbose" reports "ON_LEVEL" .


Installing the Update Release

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

To verify the VIOS update files, follow these steps:

$ oem_setup_env
Create a link to openssl
# ln -s /usr/bin/openssl /usr/ios/utils/openssl
Verify the link to openssl was created
# ls -alL /usr/bin/openssl /usr/ios/utils/openssl
Both files should display similar owner and size
# exit

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

If your current level is between 2.2.1.1 and 2.2.3.x, you have to put the 2.2.4.10 and 2.2.4.20 on the same location to apply updates in single step. The single step approach fixes an update problem with the builddate on bos.alt_disk_install.boot_images fileset.

If your current level is 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1, you need to run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

Depending on the VIOs level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES:

     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset

Applying updates

WARNING: If the target node to be updated is part of a redundant VIOS pair, ensure that the VIOS partner node is fully operational before beginning to update the target node. NOTE that for VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

The current level of the VIOS must be 2.2.2.1 or later if you use the Share Storage Pool .

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $ clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:
    • Create a directory on the Virtual I/O Server.
      $ mkdir <directory_name >
    • Using ftp, transfer the update file(s) to the directory you created.

    To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

    • Mount the remote directory onto the Virtual I/O Server:
      $ mount remote_machine_name:directory /mnt

    The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

    • Place the CD-ROM into the drive assigned to VIOS.
  5. Commit previous updates by running the updateios command

    $ updateios -commit

  6. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.

    $ cp <directory_path >/ck_sum.bff /home/padmin
    $ chmod 755 </home/padmin>/ck_sum.bff
    $ ck_sum.bff <directory_path >
    If there are missing updates or incomplete downloads, an error message is displayed.

  7. Apply the update by running the updateios command

    $ updateios -accept -install -dev <directory_name >

  8. To load all changes, reboot the VIOS as user padmin .

    $ shutdown -restart

    Note: If shutdown –restart command failed, run swrole –PAdmin in order for padmin to set authorization and establish access to the shutdown command properly.

  9. If cluster services were stopped in step 3, restart cluster services.

    $ clstartstop -start -n <cluster_name > -m <hostname >

  10. Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now 2.2.4.20.

    $ ioslevel


Performing the necessary tasks after installation

Checking for an incomplete installation caused by a loaded media repository

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command:
$ lsrep

If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

Running the lsvopt command should show the media images.

Recovering from an incomplete installation caused by a loaded media repository

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

  1. Unload any media images

    $ unloadopt -vtd <file-backed_virtual_optical_device>

  2. Reinstall the ios.cli.rte fileset by running the following commands.

    To escape the restricted shell:
    $ oem_setup_env
    To install the failed fileset:
    # installp –Or –agX ios.cli.rte –d <device/directory >
    To return to the restricted shell:
    # exit

  3. Restart the VIOS.

    $ shutdown –restart

  4. Verify that the Media Repository is operational by running this command:

    $ lsrep

Additional information

NIM backup, install, and update information

Use of NIM to back up, install, and update the VIOS is supported.

For further assistance on the back up and install using NIM, refer to the NIM documentation.

Note : For install, always create the SPOT resource directly from the VIOS mksysb image. Do NOT update the SPOT from an LPP_SOURCE.

Use of NIM to update the VIOS is supported as follows:
Ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section.

On the NIM Master, use the operation updateios to update the VIOS Server.

Sample: "nim –o updateios –a lpp_source=lpp_source1 ... ... ... "

For further assistance, refer to the NIM documentation.

On the NIM Master, use the operation alt_disk_install to update an alternate disk copy of the VIOS Server.

Sample:
"nim –o alt_disk_install –a source=rootvg –a disk=target_disk
–a fix_bundle=(Value) ... ... ...
"

For further assistance, refer to the NIM documentation.

If NIM is not used to update the VIOS, only the updateios or the alt_root_vg command from the padmin shell can be used to update the VIOS.

Installing the latest version of Tivoli TSM

This release of VIOS contains several enhancements. These enhancements are in the area of POWER virtualization. The following list provides the features of each element by product area.

Note: Version 6.1.0, the previous version of Tivoli TSM, is still shipped and installed from the VIOS installation DVD.

Tivoli TSM version 6.2.2

The Tivoli TSM filesets are now being shipped on the VIOS Expansion Pack, with the required GSKit8 libraries.

The following are sample installation instructions for the new Tivoli TSM filesets:

$ updateios -fs tivoli.tsm.client.api.32bit -dev /dev/cd0

NOTE: Any prerequisite filesets will be pulled in from the Expansion DVD, including for TSM the GSKit8.gskcrypt fileset.

  1. Insert the VIOS Expansion DVD into the DVD drive that is assigned to the VIOS partition.
  2. List Contents of the VIOS Expansion DVD.

    $ updateios -list -dev /dev/cd0
    Fileset Name
    GSKit8.gskcrypt32.ppc.rte 8.0.14.7
    GSKit8.gskcrypt64.ppc.rte 8.0.14.7
    GSKit8.gskssl32.ppc.rte 8.0.14.7
    GSKit8.gskssl64.ppc.rte 8.0.14.7
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 tivoli.tsm.client.api.64bit 6.2.2.0
    ..

  3. Install Tivoli TSM filesets.
  4. If needed, install additional TSM filesets.

    $ updateios -fs tivoli.tsm.client.ba.32bit -dev /dev/cd0

  5. Verify TSM installed by listing software installed.

    $ lssw
    Sample output:
    ..
    tivoli.tsm.client.api.32bit 6.2.2.0 CF TSM Client - Application Programming
    Interface

Fixes included in this release

The cumulative summary of fixes from previous releases (from 2.2.4.00 to 2.2.4.10)
APAR Description
IV70173 LOCAL USER LOGIN FAILS WITH LDAP ERROR MESSAGE
IV70475 RESTORE ENCRYPTED FILESYSTEM CANNOT CREATE /VAR/ADM/RAS/BI.LOG
IV70799 RPC.MOUNTD COREDUMP WITH ILLEGAL INSTRUCTION
IV70843 AIXPERT MAY ADD WRITE PERMISSION TO PROGRAMS
IV71011 V3 NFS EXPORTED VERITAS FS CONSUMES EXCESSIVE CPU
IV71031 AIX NFSSTAT COMMAND DOES NOT REPORT ATTR CACHE TIMEOUT VALUES
IV71034 PRTCONF CAN NOT REPORT PROCESSOR TYPE IN NON-ENGLISH LANGUAGE
IV71115 KERNEL ABEND CRASH IN OBJECTSREMOVE
IV71225 CREATING LARGE RAMDISK TAKES A LONG TIME
IV71257 SAP UUID_CREATE() STALLS DUE TO NDD_LOCK SERIALIZATION
IV71304 DUPLICATE PRIMARY AND TPRIMARY DUMP DEVICES IN SWSERVAT ODM.
IV71476 CLOSING SOCKET WHILE 2ND THREAD IS POLLING CAUSES HANG.
IV71481 NIMADM ON CLIENTS WITH BOS.COMPAT.LINKS INSTALLED MISBEHAVES.
IV71649 CAA: MKCLUSTER FAILS TO CREATE /ETC/CLUSTER/LOCKS DIRECTORY
IV71659 SPURR_VERSION MIGHT BE RESET TO 0 WHEN MOVING TO SMT-8 ON BRAZOS
IV71784 DEVICES CONNECTED TO USB0 NOT USABLE ON CONSOLE LFT.
IV71787 LSCLUSTER DOES NOT RECOGNIZE AN EXISTING NODE NAME
IV71806 PART FAILS TO CREATE TAR FILE AFTER SETTING HIGH SECURITY LEVEL
IV71857 AIX NFS4 SERVER CRASHES IN SM4_VCM_PURGE_RIGHTS()
IV71879 NOAC SUPPORT IN MKNFSMNT AND CHNFSMNT
IV71948 MULTIBOS TAGS INCORRECT WHEN /ETC/FILESYSTEMS.CHROOT.SAV EXISTS
IV72007 INCORRECT READ MAY OCCUR DURING JOINVG
IV72066 CLUSTER0 MISSING LEADS TO MKCLUSTER FAILURE
IV72122 NO ERRORS SEEN WHEN DUPLICATE FLAGS IN "NO" COMMAND ARE USED
IV72147 CFGIPSEC NOT PROPERLY HANDLING COMMENTS IN NEXTBOOT FILE
IV72379 SYSTEM MAY CRASH DURING I/O TO STRIPED LV WITH INFINITE RETRY
IV72499 CORE DUMP AFTER FAILED DLOPEN IN 64-BIT PROGRAM
IV72705 FSCK HANGS WHILE REPAIRING ACL INODE
IV72781 IPSECSTAT DISPLAYING NEGATIVE VALUES
IV72792 IFUNIT() CRASH WHEN IOCTL CALLED WITH WRONG SIOCGSIZIFCONF VALUE
IV72893 CLCOMD CAN USE TOO MUCH CPU WHEN AHAFS NOT ACCESSIBLE
IV73259 SUPPORT FOR CRITICAL VG ATTRIBUTE ALT_DISK_COPY/ALT_DISK_INSTALL
IV73415 JFS2 FILESYSTEM DOES NOT INCREMENT PER-CPU IGET COUNTER
IV73440 SYSTEM CRASH IN DOUBLE FREE SCSIDISK_CONFIG
IV73516 CRASH DOUBLE FREE IN SCSIDISK_TERM_MPIO
IV73528 ARTEXGET IS SLOW WITH LARGE NUMBER OF COMMANDS TO EXECUTE
IV73626 CREATING AN EXTERNAL SNAPSHOT LARGER THAN 1 TB MAY FAIL
IV73642 LSDEV -TYPE ENT4SEA EXCLUDES ROCE ADAPTER
IV73707 AIX NFSV4 SERVER CRASHES WHEN POWERHA STARTS
IV73758 EXECUTING STOPSRC -G IKE CAN HANG TMD
IV73768 EXTENDVG OF CONC VG MAY FORCE THE VG OFFLINE ON REMOTE NODE
IV73771 A JFS2 FILE OPENED WITH O_SYNC MAY HAVE ZERO LENGTH AFTER REBOOT
IV73910 KSH RUNS OUT OF MEMORY WHILE ASSIGING FEW MB DATA TO A VARIABLE
IV74173 EXT PARAMETER NOT CORRECTLY DEALT WITH IN DIO
IV74403 FUSER/PROCFILES COMMAND MAY STUCK IN AN ENDLESS LOOP
IV74417 LKDEV -L HDISK -D MAY FAIL WITH 0514-518 CANNOT ACCESS THE CULK
IV74540 CRON AND AT JOBS NOT WORKING FOR DOMAINLESS USERS
IV74606 ALT_DISK_COPY ON 4K DISK TRIGGERS LVM_IO_FAIL
IV74766 JFS2 MAY CRASH WHILE SHRINKING
IV75001 MIGRATEPV FAILURE MAY CAUSE IO HANG IN CONCURRENT VG
IV75013 HANG WHEN TRACE AND DR FOR CPU ADD STARTED AT ONCE
IV75015 DSH SOMETIMES IGNORE LAST BLANK LINES AND SOMETIMES NOT
IV75041 MEMORY LEAKS RELATE TO GET_NIS_ENTRY ROUTINE
IV75044 EXPORTING LANG=JA_JP WITHIN SCRIPT DOES NOT EFFECT
IV75059 SYSTEM HUNG WITH PSMDS HOGGING CPUS WHEN VM_PVLIST_DOHARD=1
IV75073 NIM -O UPDATEIOS COMMAND FAILS EVEN AFTER APPLYING IV60805
IV75266 INVALID FILESYSTEM UTILIZATION EVENT WITH AHAFS MONITORING
IV75273 LSLDAP KEEPS ON FAILLING WHEN LDAP SERVER CLOSES CONNECTION
IV75274 MULTIBOS REPORTS SUCCESS EVEN IF NOT ALL FILES WERE COPIED
IV75364 CAA: UNEXPECTED START_NODE BY PEER NODE LEADS TO AST PANIC
IV75387 CAA: SYSTEM WILL CRASH IF GOSSIP PACKET HAS ID = 0
IV75495 CODEGCHECK MIGHT FAIL WITH FALSE ERROR
IV75518 CAT, PIPE, GREP -L ISSUE
IV75682 SLOW MBUFS RELEASE CAUSES HIGH CPU
IV75738 LSSEC PERFORMANCE SUFFERS WHEN EFS IS ENABLED
IV75896 SYSTEM CRASH IN DBALLOCAG DUE TO ENOSPC
IV76050 THE UUID_CREATE SUBROUTINE MAY CREATE DUPLICATE UUIDS
IV76151 IKED LOOPS AND CAUSES CPU LOAD WHEN 0-BYTE DATAGRAM IS PRESENT
IV76234 SYMBOL RESOLUTION FAILURE WHEN PERFORMING A MULTIBOS UPDATE
IV76252 PASSWORD AGING DOESN'T WORK FOR LDAP IF LDAP USES LOCAL DEFAULTS
IV76409 CANNOT UNMOUNT FILE SYSTEM AFTER USING SHARED SYMBOL TABLE.
IV76503 POSIX_SPAWN FUNCTIONS MAY CORE DUMP IN 64-BIT PROGRAM
IV76508 EFSENABLE -D WRT LDAP OPERATION FAILS IN SOME SCENARIOS
IV76662 GETIOPRI(PID_T) COULD ERRONEOUSLY RETURN -1 FOR NON-ROOT USERS
IV76720 USING CHDEF WITH INCORRECT SYNTAX DOES NOT DISPLAY USAGE ERROR
IV76774 SYSTEM CRASH IN PRGETPSINFO()
IV76806 LSGROUP INCORRECTLY CACHES LDAP USER INFORMATION
IV76813 JFS2 FILE SYSTEM MAY GET J2_IMAP_CORRUPT ERROR IN ERROR LOG
IV77175 CAA: MERGE FAILURE DUE TO STALE JOIN_PENDING FLAG.
IV77529 DISK NORMAL OPEN FAILS WITH EACCES
IV77678 THE MORE COMMAND MAY FAIL TO HANDLE LARGE FILES (>=4GB)
IV77697 CIO/DIO ENABLED FILESYSTEMS CAN CRASH THE SYSTEM WITH ISI_PROC
IV78453 IMPROVED DRIVER'S FAIRNESS ALGORITHM TO AVOID I/O STARVATION
IV78454 IMPROVED DRIVER'S FAIRNESS LOGIC TO AVOID I/O STARVATION
IV78895 NPIV Migration failed with Function npiv_phys_spt tried to
IV78896 Improve SSP DB access performance
IV78897 LU-level validation for LPM fails with IBM i or Linux clients
IV78899 System crash in entcore_link_change_nic_callback()
IV78900 Removing certain virtual devices incorrectly fails.
IV78931 Console errors for VLAN over SEA

The summary of fixes in current release (2.2.4.20)

APAR Description
IV61308 HANG IN ELXENT_BUGOUT
IV64651 TRUSTCHK -A WITH A LONG ARGUMENT MAY CREATE A CORE
IV67308 VERY SLOW NETWORK THROUGHPUT FROM VIOC
IV70551 LLDPCTL PROVIDES INCORRECT NUMBER OF VSI
IV73495 PACKET LOSS UPON IMMEDIATE SEA FAILBACK AFTER LINK INITIALIZATIO
IV74411 XMTOPAS NON COLLECTION OF EXIST STATUS CAUSING ZOMBIE PROCESSES
IV74935 MKTIME()IS RETURNING INCORRECT VALUE FOR OLSON TIME ZONE FORMAT
IV74990 POOLADM PPSECTOR COMMAND CAN HANG THE POOL
IV74992 SSP POOL MAY DO EXCESSIVE ERROR RECOVERY
IV75253 FG create failed after replacing PVs
IV75480 LPM validation fails if some port bounce happens on SAN
IV75534 New mirror copies not balanced in replica set.
IV75719 FCSTAT -N WWNXXXX FCS0 RETURNS 0 FOR FCSTAT OUTPUT
IV76158 SYSTEM CRASH AFTER RENDEV ON FCS ADAPTER
IV76204 ISCSI TOE SENDING IO TO WRONG TARGET
IV76591 0514-061 CANNOT FIND A CHILD DEVICE ERRORS ON FC ADAPTERS
IV76819 After a DPO operation on a VIOS server, license check can fail.
IV77012 POST_VGSYNC ERROR 0403-004 SPECIFY A PARAMETER WITH THIS COMMAND
IV77506 CACHEFS CRASHES IN CFIND()
IV77509 ABEND IN RESET_DECV
IV77510 SYSTEM CRASH IN REMOVING THE SEA ADAPTER BY RMDEV COMMAND
IV77670 DIAG RETURNED 2E41-103: CHECKSUM VERIFICATION TEST FAILED
IV77687 ALLOW FC ATTRIBUTES TO BE SHOWN AND CHANGEABLE VIA SMIT
IV77902 Application crash during library initialization
IV77949 DSI in pkcs11 clic code
IV77964 CAA: CHREPOS -C INCORRECTLY SAVES NODE_LOCAL VALUE TO REPO DISK
IV78187 DSI IN ENTCORE_TX_SEND IN MLXENTDD
IV78360 LDAP USER HAS ADMCHG SET AFTER CHANGING OWN PASSWORD
IV78412 FAILURE OF VIOSBR (VIRTUALCFG) DOESN'T REMOVE WORKING FILES
IV78416 SECLDAPCLNTD INVALID CACHE ATTRIBUTE
IV78419 FC5899 IS MISSING SMIT PANEL FOR CHANGING MEDIA SPEED.
IV78420 NPIV adapter becomes unresponsive
IV78425 ROOTCRNJOBCK FAILS TO HANDLE RELATIVE SYMLINKS & SYMLINK CHAINS
IV78441 POSSIBLE HANG IN _KWAITPID
IV78501 LEADING WHITESPACE CAUSES ENTRIES IN RESOLV.CONF TO
IV78502 LOOPING IN EFC_FREE_LOGIN_TBLE
IV78549 CRASH DUE TO BRKPOINT IN GXIB_RAS_REGISTER CALL DURING BOOT
IV78550 AP PCM might not switch to alternate path in some scenarios.
IV78576 CRFS -A QUOTA=NO SHOULD HAVE FAILED DUE TO INVALID ATTRIBUTE
IV78830 NPIV CLIENT LPAR REBOOT CAN HANG THE VIOS
IV78884 ALT_DISK_COPY MAY FAIL WHEN MOUNTING FILESYSTEMS
IV79060 ABEND IN NMENT_FREE_RX
IV79063 FC Adapter HW Error with SRN FFC-104 and above.
IV79066 CLMIGCHECK GIVES WARNING ON SYSLOG.CONF UPDATE
IV79067 CLMIGCHECK GIVES RESERVE ERROR ON REPOSITORY DISK
IV79069 VALID AIX LEVELS MIGHT BE INCORRECTLY IDENTIFIED AS INVALID.
IV79073 MISSING INFORMATION FROM CLMIGCHECK ERROR MESSAGE
IV79074 CLMIGCHECK FAILS IF NETSVC.CONF CONTAINS COMMENTED HOSTS LINES
IV79281 CLMIGCHECK MIGHT FAIL ON CLUSTERS WITH MORE THAN TWO NODES.
IV79301 MWC/force syncvg IOs on async GLVM timeed marked PV missing.
IV79303 IO.TEM CAN CRASH DURING THE PROCESSING OF FAILED ASYNCHRONOUS
IV79471 Some SSP VTDs missing after restore operation
IV79472 microcode update on NPIV vfc device may show sw err message
IV79487 WHEN FILE IS DELETED GROUP QUOTA INFO NOT UPDATED IN JFS2
IV79489 FILESYSTEM HANG WHEN GOING INTO DEGRADED MODE
IV79516 VKE_INFO QUEUE FULL ERROR DETAIL MESSAGE
IV79658 LEVEL.OT MIGRATIONS FAIL IF ALL NODES NOT AT THE SAME CAA
IV79683 /USR FAILS TO MOUNT DURING BOSINST WITH ENCRYPTED FILESYSTEMS
IV79684 SYNTAX ERROR IN BI_MAIN TO DO ISCSICHECK
IV79710 NIMADM FAILS WHEN MASTER IS BOOTED FROM BOS_HD5
IV79729 CLASS 3 NAMESERVER QUERY ODM SUPPORT FOR LEGACY FC ADAPTER
IV79991 FAST_FAIL MAY NOT WORK WHEN THE IMM_GID_PN ENABLED
IV80044 SSHD DUMPS CORE WHEN AN LDAP USER ATTEMPTS TO LOG IN
IV80110 RACING CONDITION WITH DAT_EP_FREE() AND DAPL_EP_CONNECT()
IV80127 NIB ETHERCHANNEL WITH SR-IOV VF PORT PROBLEM
IV80151 SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS
IV80422 SYSTEM CRASH IN PAGERCONFIRM DUE TO ENOSPC
IV80426 caa node does not halt on isolation with partial sancomm config
IV80430 cluster removed from node during multisite_connect_node
IV80435 TRUSTCHK -U OUTPUT INVALID ATTRIBUTES FOR HARDLINKS & SYMLINKS
IV80569 MUSENTDD'S RECEIVE PATH HANGS WHEN IT RECEVIES CERTAIN SIZE PKT
IV80596 MKSYSB WITH -V FLAG SENDS SDTERR'S TO STDOUT
IV80597 caa: clcomd fails to handle internal bound ip address
IV80601 SYSTEM CRASH IN PRREADSTATUS()
IV80603 readvgda will fail if run from /dev dir on a 4k block size disk
IV80667 NTH AMS CLIENT WILL NOT BOOT. VRM_STREAM_FAIL
IV80689 LNCENTDD: MULTICAST ADDRS LOST WHEN PROMISCUOUS MODE TURNED OFF
IV80732 ISAKMPD CORE DUMPED IN SPI_PROTO DESTRUCTOR
IV80845 Trustchk fails to read TEp/TLP paths greater than 1024 bytes
IV80958 clmigcheck repository list for linked cluster can be truncated
IV81016 When the catalog path is invalid artex commands coredump.
IV81017 GLOBAL ENV VAR S CAN CAUSE TL/SP UPDATES TO APPLY IMPROPERLY
IV81022 ISAKMPD CORE DUMP AT COPY_REPL
IV81026 PERFORMANCE: KSH MAY EXECUTE /USR/BIN/PWD ON STARTUP
IV81103 CRASH IN DCBFLUSH_LOCAL DUE TO INVALID POINTER
IV81223 HMC reports that VIOS is busy and not responding to queries
IV81224 I/O failure may occur in QLogic FC driver during EEH recovery
IV81241 MELLANOX V2 DRIVER LOGS LINK UP AND LINK DOWN DURING REBOOT
IV81250 SMIT INSTALLP / FILTER_ALL_LATEST HANGS WITH MALLOCTYPE=WATSON
IV81253 NETSTAT -S BYTES COUNTER WRAPS AT 32 BITS
IV81297 VIO CLIENT CRASHES IN DISK DRIVER DURING LPM WITH GPFS AND PR SH
IV81351 CRASH EXECUTING LARGE 32-BIT BINARY
IV81352 VM deploy fails when using NIC adapters
IV81453 USB KBD/MOUSE OPS CAUSE X SERVER CRASH.
IV81454 DSI IN RRHBA_QUERY_NIC
IV81462 DF AND LSFS MAY LIST THE WRONG FILESYSTEM
IV81465 VIOS indicates it is busy and cannot handle the request.
IV81621 VIOS rulescfgset removes MOTD when it should not
IV81623 NIM install over VNIC with VLAN ACL mode enabled may fail.
IV81739 LPM: MIGMGR(FIND_DEVICES -T VETH) RC=8 ON DESTINATION VIOS
IV81756 VIOS may crash after using SSP image management in IBM Director
IV81758 SYSTEM HANG WHILE EXTENDING JFS2 FILE SYSTEM HAVING DISK ERRORS
IV81780 CHVG -G TAKES REMOTE NODE OFFLINE WITH LVM_SA_QUORCLOSE
IV81820 CM ATTRIBUTE: MISSING MPIOALGORITHM FOR POWERPATH PVS
IV81839 Virtual tape devices do not configure after upgrading VIOS
IV81840 DEVICE IPSEC_V4 MAY COME UP DEFINED AT BOOT
IV81850 KSH MAY SHOW AN EMPTY COMMAND IN HISTORY
IV81851 RECURSIVE POWER FUNCTION CAUSE DBX CORE DUMP "MALLOC ALLOCATION"
IV81936 May lose access to one or more NPIV disks
IV81937 Segfault may occur in ioscli vg or lv related commands.
IV81967 UPDATEIOS:REMOVING INSTALLED EFIX FAILS DUE TO GARBAGE CHARACTER
IV82079 caa unicast communication between nodes stops working
IV82080 SEGMENTATION FAULT IN RULESCFGSET IF MOTD BIGGER THAN 1024 CHARS
IV82094 INDEXING CAUSES FAILURE FOR LDAP NETGROUP USERS
IV82141 Qlogic: Excessive time for I/O failure detection
IV82145 IPREPORT DOES NOT DISPLAY TCP OPTION 14 (TCPOPT_ALTCKSUM)
IV82163 VIOS rules sets SAS disk policy incorrectly
IV82194 CRASH DURING VIOENT CALLBACK WHEN USED WITH ETHERCHANNEL
IV82195 SR-IOV TX_TIMEOUT DEFAULTS TO 30 SECONDS
IV82197 LPM-ED CLIENTS TEMPORARILY LOOSE CONNECTIVTY DUE TO RARPS.
IV82460 Adapters using driver lncentdd may crash
IV82461 VIOS may rarely crash during LUN-level validation for LPM
IV82577 UNMIRRORVG ROOTVG MAY HANG WITH FW-ASSISTED DUMP & HD6
IV82579 SLOW HA EVENT PROCESSING IN LINKED CLUSTER DUE TCPSOCK RESETS
IV82590 SYSTEM CRASH IN PAGEOUT WITH J2_METADATA_CORRUPT ERROR
IV82627 CAA(MULTICAST): A NODE MAY NOT SEE A REBOOTED NODE AS UP
IV82983 viosbr -restore not restoring other nodes except initiator node
IV83077 EEH errors observed on ethernet adapter with FC#EN0S and FC#EN0W

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"Component":"","Platform":[{"code":"PF002","label":"AIX"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}}]