IBM Security Guardium Vulnerability Assessment halts on DB2/ZOS

Troubleshooting


Problem

IBM Security Guardium Vulnerability Assessment halts on DB2/ZOS

Symptom

When running a security assessment against a DB2/ZOS datasource the assessment halts

Cause

This may be caused by a lower priority being set for the Guardium user running tests on the DB2/ZOS side

Resolving The Problem

Increase the Workload Managed (WLM) priority of the Guardium tasks from default priority to service class DDFLO_PR on the DB2/ZOS system

[{"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Guardium Database Vulnerability Assessment","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"10.0;10.1;9.0;9.1;9.5","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]

Document Information

Modified date:
16 June 2018

UID

swg21987170