IBM Support

IBM Maximo Application Suite - Manage Component patch 8.7.9

Fix Readme


Abstract

On 25 June 2024, IBM released IBM® Maximo® Application Suite Manage Component patch 8.7.9.

Content

For Industry Solutions Patches, go to:
IBM Maximo Civil Infrastructure 8.5 (patches 8.5.14 & 8.6.10)

Manage and Mobile APAR and Known Issue Fixes
When an APAR or Known Issue has Manual Change in the first column, click the link or go to the Manual Changes section for directions.
When an APAR or Known Issue has Behavior Change in the first column, click the link or go to the Behavioral Changes section for information.
APAR Application Name Description
DT238874 Install/Upgrade In an upgrade environment that has a table with a column of data type CRYPTO, and one or more records in that table has data in the CRYPTO field, the upgrade fails in ValidateCrypto.
DT253536 Users The CognosUserSyncCronTask does not synchronize Users from MAS Core to Cognos if they were already synchronized from MAS Manage to MAS Core.
DT258311
Manual Change
Inventory Counting Count Book Lines show the wrong serial number for Assets.
DT258796 System properties In environments where the value of the System Property mxe.java.checkIntegerBoundaries is true, administrators cannot an Organization.
DT260224 Login When logging in with a SAML user, 2 JSESSIONIDs are created. When the user logs out, the first JSESSIONID remains active while the second is ended properly.
DT261549 Assets In Assets, entering unavailable hours outside the Shift Period causes Asset Downtime to be incorrect.
DT269884 System UI Chrome does not render diacritics in capital letters correctly in Chrome.
DT380456 Mobile Maximo Mobile application crashes with OOM error.
DT380837 Graphical Assignment In environments where the System Property mxe.map.showMarkersOnRouteError is set to 1, the Graphical Assignment map displays no Work Order markers for routes.
DT381315 Inventory Counting When a Count Book status is changed from INPRG to PCCOMP, trying to Reconcile item balances results in error BMXAA9949E - "This action is not allowed for the current status.".
DT381523 Mobile The MobileDbGeneration cron task generates a preload DB with missing Attributes.
DT381711 Mobile In the Work Order for EAM application, clicking the Start-Stop timer repeatedly causes the error "missing key value info" to display.
DT381883 Mobile The Failure Class and Problem do not display after the user fills in the Failure report.
DT381946 Mobile Updating the Cause and Remedy of a Failure Report results in error BMXAA0018I - "The report is complete.".
DT382172 Mobile Mobile displays only Completed Tasks, not Active and Completed Tasks.
DT382232 Mobile In the Mobile Technician application, Route Stops are not ordered by Sequence.
DT382276 Mobile In the Mobile Technician application, setting the Start Time in a Work Order to more than 3 hours displays "Start time cannot be in the future" message even though Future Labor Transaction Tolerance in Hours is set to longer than that. The user cannot save the Actual Labor.
DT382297 Mobile Mobile application allows fields in closed Work Orders to be edited.
DT382444 System UI In the Work Order role-based application an image added to the Long Description of a Work Order is not displayed.
DT383008 Mobile Maximo Mobile generates heap dumps.
DT383276 Mobile In Mobile Inspections, clicking a Work Order number displays the incorrect Work Order.
DT385969 System UI In the Maximo Mobile Technician application, the cs-switch text translations are not published.
DT386200 Mobile A user cannot create a follow-up Work Order when the parent Work Order does not belong to the list specified in the Security Group condition.
DT386275 Mobile Labor Hours disappear from the Report Work page on a Mobile device.
DT386333 Mobile In the Technician role-based application, reporting Labor does not display the Labor Name.
IJ38911 Work Order Tracking The Skill Level on the Assignments tab is not copied when a Work Order is duplicated.
IJ44914 Scheduler In Graphical Scheduling, clicking "Select All Tree Grid" does not work as expected.
IJ48388 Integration In the Maximo Integration Framework (MIF), Location movement suppresses other field validation.
IJ49357 Create Requisition Creating a Requisition from a Template with a Line Type Tool and Line Type Part causes error BMXMB0547E - "Item xxxx does not exist in this line type.".
IJ49361 Crafts In the Work Order Tracking application, on the Actuals tab, the Premium Pay Code is not updated when the Craft is changed.
IJ49630 Drilldown Clicking a hyperlink from the Locations extended drill-down does not open the selected Location.
IJ49678 Inventory Counting When performing an inventory counting for an item with Item Cost Type LIFO, the INVLIFOFIFOCOST lines are not updated.
IJ49745 Calibration Clearing As Found Input/Output values dies not clear Calibration Point Tolerance values.
IJ49869 Automation Scripts In Automation Scripting, selecting the Close Work Order action from the List View does not trigger the Attribute Launch Point Script.
IJ49930 Manage Inspection Inspection Form displays the error BMXAA2890E for all values entered in the run hours field.
IJ49991 System UI In Preventive Maintenance, adding column controls with conditions to the PR Lines section causes unexpected read-only conditions and system messages.
IJ50093 Integration Updating SAFETYPLANID on existing Work Orders using Integration results in error BMXAA4134E - ""SAFETYPLANID did not validate.".
IJ50471 Purchase orders When trying to navigate to Purchase Orders application from an Inventory Reservation record that has a Storeroom Site different than the To Site field, user is taken to a blank list view of the PO Tracking application, instead of being taken to the actual PO record.
IJ50475 Report Direct Print with Attachments fails when the file name includes a parenthesis.
IJ50718 Work Order Tracking In the Work Order Tracking application, on the Plans Tab, no data is displayed selecting a Labor value as a filter.
IJ50792 Assets Changing an Asset's status to a synonym of Decommissioned, then changing the status of its Location to a synonym of Decommissioned causes duplicate lines to be written to the Asset Status History.
IJ50821 Graphical Resource View In the Graphical Resource View application, double-clicking on a day does not schedule the entire week if the MODAVAILDURTYPE domain is in a language that contains special characters, such as Japanese, Chinese or Czech.
IJ51001 Integration Importing Hazards have the Organization ID of the MXINTADM user and not the Organization specified in the file.
IJ51004 Asset templates In the Assets Template, the Meter Group field is read-only when no Meters are associated with it.
IJ51006 Meters In Asset Templates application, the Meters in the previous Meter Group remain when the Meter group is changed.
IJ51008 System Object Maximo generates DEBUG level log entries for some objects, bypassing the Maximo Logger's application settings.
IJ51035 Inventory usage Clicking the action "Create Remaining Usage Lines" does not populate the GL Debit Account.
IJ51043 Tools In the Tools application, checking the "Rotating Item" checkbox results in error BMXAA9922 - "This item is active and has been added to a storeroom. It cannot be made rotating.".
IJ51081 Inventory usage When Required Dates are updated on a Work Order Materials tab, the Inventory Usage records are not regenerated properly.
IJ51093 System UI The CASSSPECVALUE Attribute does not display DATE type values.
IJ51199 Inspection In the "Conduct an Inspection" Work Center, the action "Generate Work Order for items" results in error BMXAA7837E - "An error occurred that prevented the OSACTION.MXAPIINSPRESULT.CREATEWO script for the null launch point from running. AttributeError: 'NoneType' object has no attribute 'createWorkorder' in script at line number 33.".
IJ51206 Manage Inspections Forms In the Manage Inspection Forms Work Center, Conditional Settings functionality does not work.
Manual Changes
APAR Change instructions
1. Go to the Database Configuration Application
2. Query for "COUNTBOOKLINE" object and move to Relationship tab
3. Search for a Relationship called ASSET
4. Update the where clause from
   itemnum=:itemnum
    to
   itemnum = :itemnum and assetnum=:assetnum and siteid=:siteid and orgid=:orgid
5. Click Save


Manually Installing the Patch
  • Log in to Maximo Application Suite Administration as an administrative user.
  • On the left, click Applications.
  • From the Action menu, select Update configuration.
  • In the dialog box, click the pencil icon on the Components line.
  • Under Activation configuration, click your workspace details page link.
  • From the Action menu, select Update configuration.
  • Under Configurations, click the pencil icon on the Components line.
  • In the Maximo Base line, under new version click the down arrow.
  • Starting with Manage patch 8.7.9, the Manage workspace component selection does not show version number.
  • Select Version, then latest.
  • Click Save.

[{"Type":"MASTER","Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSRHPA","label":"IBM Maximo Application Suite"},"ARM Category":[{"code":"a8m3p000000hB0QAAU","label":"Manage"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.7.0"}]

Document Information

Modified date:
10 July 2024

UID