External options, connecting external SCSI devices, and input/output ports and connectors - Netfinity 5500 M20

Product Documentation


Abstract

Diagram of external options, connecting external SCSI devices, and input/output ports and connectors

Content

External options

NOTE:
  • Read "Safety Information" in the Hardware Maintenance Manual (HMM).
  • Read the documentation that comes with the options.

Connecting external SCSI devices: You can attach a SCSI storage expansion enclosure to your server.

Cabling requirements: The ServeRAID controller in the server has one channel that can be used to attach external devices. This channel is connected to the SCSI connector on the back of the server. To select and order the correct cables for use with external devices, contact your IBM reseller or IBM marketing representative.

Refer to "ServeRAID system board controller" in the HMM to determine the number of internal and external connectors, channels, and SCSI devices that the controller supports.

For information about the maximum length of SCSI cable between the terminated ends of the cable, see ANSI SCSI Standards:
  • X3.131-1986 (SCSI)
  • X3.131-1994 (SCSI-2)
  • X3T10/1071D

Adhering to these standards ensures that the server operates properly.

Setting SCSI IDs for external devices: Each SCSI device that is connected to a SCSI controller must have a unique SCSI ID, so that the SCSI controller can identify the devices and ensure that different devices do not attempt to transfer data at the same time. SCSI devices that are connected to different SCSI controllers can have duplicate SCSI IDs. See "SCSI IDs" and refer to the instructions that come with the SCSI devices for more information about setting a SCSI ID.

Installation procedure to attach an external device:

  1. Turn off the server and all attached devices.
  2. Follow the instructions that come with the option to prepare it for installation and to connect it to the server.

Input/output ports and connectors: The input/output (I/O) connectors are for attaching external devices, such as printers, keyboards, and displays, to your server. The I/O connectors on your server include:

  • Two serial-port connectors
  • One systems management connector
  • One parallel-port connector
  • One video-port connector
  • One keyboard-port connector
  • One auxiliary-device-port connector
  • One SCSI port connector
  • One Ethernet-port connector
  • Two USB-port connectors
  • One RS-485-port connector
Serial ports: The server comes with two serial ports. (See "Input/output connectors and expansion slots" in the Hardware Maintenance Manual for the locations of the connectors.) These ports are used to communicate with printers, plotters, external modems, scanners, and auxiliary terminals. These ports also enable you to transfer data between computers.

Serial ports can transfer data asynchronously, which means that they can transmit any number of characters at any time, with no restriction on the duration of the pauses between characters.

The serial ports can transmit and receive data and commands at rates of from 300 bits per second up to 115 000 bits per second.

Serial port A is shared by the operating system and the integrated Netfinity Advanced System Management Processor. Serial port B can be used only by the operating system.

Each serial port has a 9-pin, male D-shell connector on the back of the server. The pin-number assignments of this connector conform to the industry standard.

pin assignments

The following table shows the pin-number assignments for the serial-port connectors.

Table 3. Serial port pin-number assignments
Pin Signal Pin Signal
1
Data carrier detect
6
Data set ready
2
Receive data
7
Request to send
3
Transmit data
8
Clear to send
4
Data terminal ready
9
Ring indicator
5
Signal ground
.
.

When you turn on your server, the POST routine assigns the serial ports to specific communication port addresses.

Some application programs use only certain ports, and some modems are designed for use only at certain communication port addresses. You might need to use the Configuration/Setup Utility program to change communication port address assignments to resolve conflicts.

Management port C: The server has a dedicated system-management I/O port. This port can be used to attach a modem that is dedicated to communication with the Netfinity Advanced System Management Processor.

The connector on the back of the server and the pin-number assignments are the same as for the serial ports.

Parallel port: The parallel port usually is used to communicate with printers, and transfers data one byte at a time. The parallel port has a 25-pin, female D-shell connector on the back of the server. It support three standard IEEE 1284 modes of operation: Standard Parallel Port (SPP), Enhanced Parallel Port (EPP), and Extended Capability Port (ECP). (See "Input/output connectors and expansion slots" for the location of the connector.)

pin assignments

The following table shows the pin-number assignments for the parallel-port connector.

Table 4. Parallel port pin-number assignments
Pin I/O SPP/ECP Signal EPP Signal
1
O
-STROBE
-WRITE
2
I/O
Data 0
Data 0
3
I/O
Data 1
Data 1
4
I/O
Data 2
Data 2
5
I/O
Data 3
Data 3
6
I/O
Data 4
Data 4
7
I/O
Data 5
Data 5
8
I/O
Data 6
Data 6
9
I/O
Data 7
Data 7
10
I
-ACK
-ACK
11
I
BUSY
-WAIT
12
I
PE (paper end)
PE (paper end)
13
I
SLCT (select)
SLCT (select)
14
O
-AUTO FD (feed)
-DSTRB
15
I
-ERROR
-ERROR
16
O
-INIT
-INIT
17
O
-SLCT IN
-ASTRB
18
-
Ground
Ground
19
-
Ground
Ground
20
-
Ground
Ground
21
-
Ground
Ground
22
-
Ground
Ground
23
-
Ground
Ground
24
-
Ground
Ground
25
-
Ground
Ground


When you turn on your server, the POST routine assigns the parallel port a specific port address. You can change the parallel-port assignment by using the Configuration/Setup Utility program.

Video port: The system boardin your server has one SVGA video port. This port is used to attach a video monitor. Thevideo port has a 15-pin analog connector on the back of the server. (See "Input/output connectors and expansion slots" in the Hardware Maintenance Manual for the locations of the connector.)
pin assignments

The following table shows the pin-number assignments for the video connector.

Table 5. Video port pin-number assignments
Pin Signal
1
Red
2
Green or monochrome
3
Blue
4
Monitor ID bit 2
5
Ground
6
Ground
7
Ground
8
Ground
9
+5 V dc
10
Ground
11
Monitor ID bit 0
12
DDC SDA
13
Horizontal synchronization (Hsync)
14
Vertical synchronization (Vsync)
15
DDC SDL


Keyboard and auxiliary-device ports: The system board has one keyboard port and one auxiliary-device port that supports a mouse or other pointing device. (See
"Input/output connectors and expansion slots" in the Hardware Maintenance Manual for the locations of the connectors.)
keyboard and auxiliary-device port

The following table shows the pin-number assignments for the connectors used by the keyboard and auxiliary-device ports.

Table 6. Keyboard and auxiliary-device port pin-number assignments
Pin Signal
1
Data
2
Not connected
3
Ground
4
+5V dc
5
Clock
6
Not connected


SCSI port: Your server comes with a RAID controller on the system board, which provides two independent SCSI channels. A 16-bit (wide) SCSI cable connects the hot-swap backplane to one channel of the integrated RAID SCSI controller. Another SCSI cable connects the other channel of the controller to the SCSI connector on the rear of the server.

To attach an external SCSI device to your server, connect an external SCSI cable from the SCSI device to the SCSI connector on the back of the server. Ensure that the last device on the external SCSI cable is terminated. Table 7 shows the pin-number assignments for the 68-pin SCSI connectors.

Table 7. 68-pin SCSI port connector pin-number assignments
Pin Signal Pin Signal
1
Ground
35
Data 12
2
Ground
36
Data 13
3
Ground
37
Data 14
4
Ground
38
Data 15
5
Ground
39
Data P1
6
Ground
40
Data 0
7
Ground
41
Data 1
8
Ground
42
Data 2
9
Ground
43
Data 3
10
Ground
44
Data 4
11
Ground
45
Data 5
12
Ground
46
Data 6
13
Ground
47
Data 7
14
Ground
48
Data P0
15
Ground
49
Reserved
16
Ground
50
-PRSN
17
Terminal power
51
Terminal power
18
Terminal power
52
Terminal power
19
Reserved
53
Reserved
20
Ground
54
Ground
21
Ground
55
-Attention
22
Ground
56
Ground
23
Ground
57
-Busy
24
Ground
58
-Acknowledge
25
Not connected
59
-Reset
26
Ground
60
-Message
27
Ground
61
-Select
28
Ground
62
-Control/Data
29
Ground
63
-Request
30
Ground
64
-Input/Output
31
Ground
65
Data 8
32
Ground
66
Data 9
33
Ground
67
Data 10
34
Ground
68
Data 11


Ethernet port: The system board in your Netfinity 5500-M10 contains an Ethernet controller. The controller has an external RJ-45 connector on the rear of the server that is used with a category 3, 4, or 5 unshielded twisted-pair (UTP) cable. The connector enables an Ethernet network to attach to the internal transceiver in your server.

NOTE:
The 100BASE-TX Fast Ethernet standard requires that the cabling in the network be Category 5 or higher.


See "Configuring the Ethernet controller" in the HMM for additional information about the Ethernet controller.

Table 8 shows the pin-number assignments for the RJ-45 connector. These assignments apply to both 10BASE-T and 100BASE-TX devices.
connector


Table 8. Ethernet connector pin-number assignments
Pin Signal Pin Signal
1 Transmit data+ 5 Reserved
2 Transmit data- 6 Receive data-
3 Receive data+ 7 Reserved
4 Reserved 8 Reserved


Universal serial bus ports: The system board in the Netfinity 5500 M20 contains two universal serial bus (USB) ports. Each USB port has an external connector on the rear on the server for attaching devices that previously used serial, parallel, keyboard, mouse, and game ports.

USB is an emerging serial interface standard for telephony and multimedia devices. USB technology uses Plug and Play to determine what device is attached to the connector. Each USB device is accessed by a unique USB address. A device called a hub is used to convert the USB port into multiple attachment points. A hub has multiple ports where peripherals can be attached. USB provides 12 megabits-per-second (Mbps) bandwidth with a maximum of 63 peripherals and a maximum signal distance of five meters (16 ft.) per segment.

NOTE:
If more than one USB device is to be attached, then the device must be connected to a hub.

Table 9 shows the pin-number assignments for the USB connectors.

Table 9. USB connector pin-number assignments
Pin Signal
1
VCC
2
-Data
3
+Data
4
Ground

RS-485 port: The system board has an RS-485 port that can be used by the Advanced System Management processors of several servers mounted in a rack enclosure to communicate with each other in half-duplex mode.

Table 10 shows the pin-number assignments for the RS-485 connector.
rs-485 connector

Table 10. RS-485 port pin-number assignments
Pin Signal
1
+5 V dc
2
+Data (tied to pin 4)
3
-Data (tied to pin 5)
4
+Data (tied to pin 2)
5
-Data (tied to pin 3)
6
Ground

Document Location

Worldwide

Operating System

Older System x:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU02PAO","label":"Older System x->Netfinity 5500 M20->8662"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
24 January 2019

UID

ibm1MCGN-45WLLV