Preventive Service Planning
Abstract
Configuration Information for Exabyte Magnum 224, Exabyte Magnum 448, Fujitsu-Siemens FibreCAT TX24, Fujitsu-Siemens FibreCAT TX48, Tandberg Data StorageLibrary T24, and Tandberg Data StorageLibrary T48 Libraries
Content
Exabyte Magnum 224
Exabyte Magnum 448
Fujitsu-Siemens FibreCAT TX24
Fujitsu-Siemens FibreCAT TX48
Tandberg Data StorageLibrary T24
Tandberg Data StorageLibrary T48
Model | Drive Addresses | Storage Slot Addresses | Changer Address | Entry/Exit Slot Address |
Magnum 224, TX24, T24 | 81-82 | 1-23 | 97 | 113 |
Magnum 448, TX48, T48 | 81-84 | 1-48 | 97 | 113 |
Notes:
1. Library capacity
- Magnum 224, TX24, and T24 - 2 drives 24 slots
Magnum 448, TX48, and T48 - 4 drives 48 slots
2. Barcodes are supported.
3. Device identifications and firmware levels
- Exabyte Magnum 224
Library : EXABYTE MAGNUM 224 --- Firmware : C113
- Exabyte Magnum 448
Library : EXABYTE MAGNUM 448 --- Firmware : C113
- Fujitsu-Siemens TX24
(Validated with TSM 5.3.4)
Library : FSC FibreCAT TX24 --- Firmware : C113
Drive : HP Ultrium 2-SCSI --- Firmware : S33U
- Fujitsu-Siemens TX48
Library : FSC FibreCAT TX48 --- Firmware : C113
- Tandberg Data StorageLibrary T24
Library : EXABYTE MAGNUM 224 --- Firmware : C113
- Tandberg Data StorageLibrary T48
Library : EXABYTE MAGNUM 448 --- Firmware : C113
4. ELEMent=AUTODetect in the DEFINE/UPDATE DRIVE command is supported.
5. Available drives
- Exabyte Magnum 224, Magnum 448
- HP LTO-2, HP LTO-3
- IBM ULTRIUM-TD4 (Firmware 74H4)
Fujitsu-Siemens TX24, Fujitsu-Siemens TX48
- Tandberg Data StorageLibrary T24 and T48
Library and drive may require different minimum Tivoli Storage Manager levels. Therefore, ensure that both library and drive hardware are supported. See "Supported Devices for AIX, HP-UX, Solaris and Windows" or "Supported Devices for Linux" for minimum supported version levels and platforms for these devices.
More information regarding device configuration is available in the Tivoli Storage Manager Administrator's Guide, which can be found in the IBM Tivoli Storage Manager information center.
[{"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Server","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"All Supported Versions","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]