Problem

I.T. administrator apptempts to install the Controller client (for example 'ControllerClient.MSI'), but receives error message.

Symptom


Screen:
There is a problem with the Windows Installer Package. A script required for this install to complete could not be run. Contact your support personnel or package vendor.


Event Viewer (Application Log):
Event Type: Warning
Event Source: Enigma
Event Category: None
Event ID: 0
Date: 2/21/2006
Time: 2:46:05 PM
User: N/A
Computer: machineName
Description:
Error occured at 2/21/2006 2:46:05 PM in Cognos Controller, Error No=10000, Source=xFran.SetAnyRegSetting, Description=Error saving registry settings!!, HelpFile= HelpContext=0

Event Type: Warning
Event Source: Enigma
Event Category: None
Event ID: 0
Date: 2/21/2006
Time: 2:46:05 PM
User: N/A
Computer: machineName
Description:
Error occured at 2/21/2006 2:46:05 PM in CCR, Error No=10000, Source=xFran.SetAnyRegSetting, Description=Error saving registry settings!!, HelpFile= HelpContext=0

Event Type: Information
Event Source: MsiInstaller
Event Category: None
Event ID: 11708
Date: 2/21/2006
Time: 2:45:49 PM
User: domain\username
Computer: machineName
Description:
Product: Cognos Controller Client -- Installation failed.
Data:
0000: 7b 31 43 46 44 36 43 42 {1CFD6CB
0008: 30 2d 41 45 31 39 2d 34 0-AE19-4
0010: 30 31 46 2d 38 45 44 34 01F-8ED4
0018: 2d 37 32 46 33 46 35 36 -72F3F56
0020: 42 45 31 30 45 7d BE10E}

Event Type: Error
Event Source: MsiInstaller
Event Category: None
Event ID: 11720
Date: 2/21/2006
Time: 2:45:49 PM
User: domain\username
Computer: PCNAME
Description:
Product: Cognos Controller Client -- Error 1720. There is a problem with this Windows Installer package. A script required for this install to complete could not be run. Contact your support personnel or package vendor. Custom action CognosUnregisterComponents script error -2147319779, : Line 7, Column 1,
Data:
0000: 7b 31 43 46 44 36 43 42 {1CFD6CB
0008: 30 2d 41 45 31 39 2d 34 0-AE19-4
0010: 30 31 46 2d 38 45 44 34 01F-8ED4
0018: 2d 37 32 46 33 46 35 36 -72F3F56
0020: 42 45 31 30 45 7d BE10E}

Cause

There are several potential causes for the error 'There is a problem with the Windows Installer Package. A script required for this install to complete could not be run'. For more examples, see section 'Related Documents' at the end of this IBM Technote.

However, this IBM Technote specifically relates to the scenario where the required shared Windows component "wshom.ocx" was not registered correctly on the client device (for example, end user's PC). This will cause the required script 'wcsript.shell.run' to fail.

Resolving The Problem

Re-register the component "wshom.ocx" on the client device.

Steps:

  1. Logon to the client device (for example, end user's PC) as an administrator
  2. Click 'START - RUN'
  3. CMD <Enter>
  4. regsvr32 /u C:\WINDOWS\System32\wshom.ocx <Enter>
  5. regsvr32 C:\WINDOWS\System32\wshom.ocx <Enter>

[{"Product":{"code":"SS9S6B","label":"IBM Cognos Controller"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Controller","Platform":[{"code":"PF033","label":"Windows"}],"Version":"8.4;8.3;8.2;8.1","Edition":"Not Applicable","Line of Business":{"code":"LOB10","label":"Data and AI"}}]