Troubleshooting
Problem
Error Messages: WH0987: Invalid Instruction Type, WH3991: Order Instruction Record Already Exists
Symptom
PART: Interface 6.0 SP1 DCS
COMPONENT: <None>
OS: <None> -
<None>
DATABASE: <None> - <None>
WEB SERVER: <None> - <None>
WEB
BROWSER: <None> - <None>
Error codes WH0987 and WH3991 in alert log
during order download; certain records not processed.
Cause
Resolving The Problem
--Ascertain whether any changes have been made to order-related record types
(ORDHDR, etc.). If field lengths are modified in one, the same modifications
need to be made in all related record types.
--Determine the record
type at fault from the WMS alert log.
Sample log:
WH01 |246839
|13 |WH0987 |0 |0 |3 |5144465 /001- ^^ORDINS^5144465 00
1^47 |
|whs_err_code.c |869 |WH0987:Invalid instruction type . |3 |2001020210565
8
|yantra |BU083
In this example, the record type is ORDINS
--Check
the record type ORDINS (or the setup in function ID 07002); the infc_dnld_tab_1
data is not being parsed correctly. The key is order_no, order_rel_no,
order_prime_line, order_sub_line, so this combination should always be unique.
Determine what is being parsed based on the setup in function ID 07002 (for
starting positions and field lengths) from the table.
The following
query will also display the relevant information:
Select
substr(interface_data,6,6),
substr(interface_data,14,13)
order_no,
substr(interface_data,27,3)
order_line,
substr(interface_data,30,5) prime
from
infc_dnld_tab_1
where whse = '&whse'
and interface_type = 'ORDD'
and
interface_data like '%<order_no>%'
The field which is not being read
correclty must be corrected for starting position and/or length using function
ID 07002.
Historical Number
PRI48163
Product Synonym
[<p><b>]Fact[</b><p>];