Problem

After stopping Message Engine(ME) you notice the following in the SystemOut.log.

Symptom

[3/18/12 9:28:58:437 EDT] 0000007b SystemOut O javax.jms.JMSException: CWSIA0085E: An exception was received during the call to the method JmsMsgConsumerImpl.stop: com.ibm.wsspi.sib.core.exception.SISessionUnavailableException: CWSIP0177E: The consumer session on destination connections.events on messaging engine Clus01.000-Bus01 has been closed.

Cause

In this case the CWSIA0085E error was caused by the client application not being shutdown before the ME was stopped. Reviewing the SystemOut.log showed this sequence of events
....
[3/18/12 9:28:58:404 EDT] 00000060 SibMessage I [Bus01:Clus01.000-Bus01] CWSID0016I: Messaging engine Clus01.000-Bus01 is in state Stopping.
.
[3/18/12 9:28:58:437 EDT] 0000007b SystemOut O javax.jms.JMSException: CWSIA0085E: An exception was received during the call to the method JmsMsgConsumerImpl.stop: com.ibm.wsspi.sib.core.exception.SISessionUnavailableException: CWSIP0177E: The consumer session on destination connections.events on messaging engine Clus01.000-Bus01 has been closed..
....
The ME can be seen going into stopping state before the CSWIA0085E error occured.

Resolving The Problem

You may want to stop any applications connecting to the ME before stopping the ME to prevent this type of error.

[{"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Application Client","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"8.5.5;8.0;7.0","Edition":"Base;Network Deployment","Line of Business":{"code":"LOB45","label":"Automation"}}]