Troubleshooting
Problem
Cast Iron orchestrations are getting stuck and requires a reboot of the virtual appliance to get them back to running state
Cause
This has been identified as a product defect under APAR LI78085
Diagnosing The Problem
Setting up SNMP notifications is leading to the project getting into stuck state.
Resolving The Problem
This has been identified as a product defect under APAR LI78085. As a workaround, disable SNMP notifications.
[{"Product":{"code":"SSRQYV","label":"WebSphere Cast Iron Hypervisor Edition Standard"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Appliance Runtime","Platform":[{"code":"PF016","label":"Linux"}],"Version":"6.3.0.2","Edition":"Virtual","Line of Business":{"code":"LOB45","label":"Automation"}}]
Was this topic helpful?
Document Information
Modified date:
15 June 2018
UID
swg21679160