IBM Support

VM66687: Z/VM PERFORMANCE DATA PUMP

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Enhancements to z/VM Performance Toolkit to integrate
    z/VM performance data into real-time dashboards.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/VM Performance Toolkit who    *
    *                 need to make z/VM performance data           *
    *                 available to other services.                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    New function is provided in z/VM Performance Toolkit to
    integrate z/VM performance data in an existing Splunk
    observability platform to populate real-time dashboards and
    generate reports.
    
    For customers who prefer an open-source solution, data can be
    sent to the InfluxDB time-series database where performance data
    from different sources can be retained and visualized using
    Grafana real-time dashboards. Sample dashboards for Grafana are
    available. Customers who wish to deploy InfluxDB and Grafana in
    a Linux guest on z/VM can use the container images available in
    the IBM Z Container Registry.
    

Problem conclusion

Temporary fix

Comments

  • To use the z/VM Performance Data Pump, a new DATAPUMP service
    virtual machine must be defined to connect to the *MONITOR CP
    System Service and collect performance data. A TCP/IP connection
    is used to send the data to the Splunk or InfluxDB service
    defined in the Data Pump configuration file.  When running a
    Single System Image (SSI) cluster, the DATAPUMP service virtual
    machine runs in each member of the cluster to collect data from
    that member. Tooling is provided to simplify management of the
    configuration files in such a configuration.
    
    Ideally, all z/VM systems will send performance data to a single
    Splunk or InfluxDB service. This allows enterprise-wide
    aggregation of performance data and monitoring of multiple z/VM
    systems in a single dashboard.
    
    For a secure connection between the Data Pump and Splunk or
    InfluxDB, z/VM System SSL is used. This leverages the existing
    SSL configuration to comply with company security policy.
    
    Appendix I is added to "z/VM: Performance" (SC24-6301-73).
    The "z/VM: Other Components Messages and Codes" publication
    (GC24-6300-73) is updated to include the Data Pump messages.
    HELP files are also provided for Data Pump configuration and
    messages.
    
    For publication change details, consult the updated PDF
    instances of the aforementioned publications, which are
    available via this URL:
      https://www.ibm.com/docs/en/zvm/7.3
    
    Additional information about sample dashboards for Grafana and
    deployment of InfluxDB and Grafana containers with Linux on z/VM
    is available at https://www.vm.ibm.com/related/perfkit/datapump/
    

APAR Information

  • APAR number

    VM66687

  • Reported component name

    PERF TOOLKIT

  • Reported component ID

    568411218

  • Reported release

    730

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2023-05-09

  • Closed date

    2023-08-10

  • Last modified date

    2023-11-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UM90334

Modules/Macros

  • DATAPUMP DPCONFIG DPDUMP   DPINFLUX DPMONITO DPMONWRI DPSFS
    DPSPLUNK DPSTAT   FCX      FCXBLREP FCXBLSAM FCXUME   FCXUMEB
    FCX3000I FCX3001E FCX3002E FCX3003E FCX3004E FCX3005E FCX3006E
    FCX3007E FCX3008E FCX3009E FCX3010E FCX3011E FCX3012E FCX3013E
    FCX3014E FCX3015E FCX3016E FCX3017E FCX3018E FCX3019E FCX3020E
    FCX3021E FCX3024E FCX3025E FCX3030I FCX3031I FCX3099E MDXDICT
    MDXSETUP MDXUTILX PERFKIT  PERFORM  PROFPUMP
    

Publications Referenced
SC24630173GC24630073   

Fix information

  • Fixed component name

    PERF TOOLKIT

  • Fixed component ID

    568411218

Applicable component levels

  • R730 PSY UM90334

       UP23/08/11 P 2301

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG27M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"730"}]

Document Information

Modified date: