VM66300: ABENDHTT001 HARD ABEND SETTING ISOLATION OFF FOR VSWITCH

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a SET VSWITCH xxxx ISOLATION OFF command is entered for a
    VSwitch with an UPLINK NIC, an HTT001 abend occurs.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of VSWITCH with an UPLINK NIC.     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    An HTT001 abend will occur when using a VSwitch configured with
    an UPLINK NIC port.  The abend will occur on z/VM 6.4 and z/VM
    V7.1 when turning ISOLATION ON or OFF via the SET VSWITCH
    command.
    The abend may also occur on z/VM V7.1 when sending data out the
    UPLINK NIC port.
    

Problem conclusion

  • The code to process the ISOLATION operand (HCPSWS) on the SET
    VSWITCH command has been changed to verify that LANRRDEV is
    non-zero before using that value. For a VSWitch with an UPLINK
    NIC, LANRDDEV will always be zero.
    For z/VM V7.1, HCPVNS has also been changed to properly handle
    datagrams sent out an UPLINK NIC port.
    

Temporary fix

  • *********
    * HIPER *
    *********
    FOR RELEASE VM/ESA CP/ESA R640 :
    PREREQ: VM65918
    CO-REQ: NONE
    IF-REQ: NONE
    FOR RELEASE VM/ESACP/ESAR710 :
    PREREQ: VM66219 VM66265
    CO-REQ: NONE
    IF-REQ: NONE
    

Comments

APAR Information

  • APAR number

    VM66300

  • Reported component name

    VM CP

  • Reported component ID

    568411202

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-06-24

  • Closed date

    2019-08-12

  • Last modified date

    2021-02-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UM35508 UM35509

Modules/Macros

  • HCPSWS   HCPVNS
    

Fix information

  • Fixed component name

    VM CP

  • Fixed component ID

    568411202

Applicable component levels

  • R640 PSY UM35508

       UP19/08/25 I 1000 ¢

  • R710 PSY UM35509

       UP19/08/25 P 2001 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"640","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]